-64-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
236 Lamp changer * Mirror adjustment
0 Mirror Adjust Mode 0: Normal, 1: Lamp1 Adj, 2: Lamp2 Adj. 0 - 2 0
1 Lamp Mode Lamp1
Lamp1 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
- -
2 Lamp Mode Lamp2
Lamp2 Status
0: Lamp1 not selected (Select when value is set to 10.)
11: Lamp 1 selected
99: After lamp changed
- -
10 Lamp1/Lamp2 Change Time Sets Lamp CHange Time (unit: hour) 0 - 255 10
20 Lamp Timer On/Off Lamp Timer 0: On, 1: Off 0 - 2 0
21 Lamp Timer Start Starting Time Set (h) 0 - 24 0
22 Lamp Timer Conut Timer Count Set (h) -
23 Lamp Timer Interval Interval (h) 1 - 255 24
24 Lamp Timer Store
Timer Store
0: Timer Clear after Power Off
1: Memorized
0 - 1 0
240 Flow Calibration
0 Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1 0
* Wind sensor
calibration.
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
- 255
2 Clog Check Enable Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
3 Air Inlet Check Enable Intake Error Detection vy Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
241 Flow Ideal Data (Value will be set after calibration)
0 Flow Ideal Data 1 Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1 0 - 1023 242
1 Flow Ideal Data 2 Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2 0 - 1023 275
2 Flow Ideal Data 3 Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3 0 - 1023 309
3 Flow Ideal Data 4 Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4 0 - 1023 335
4 Flow Ideal Data 5 Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5 0 - 1023 359
5 Flow Ideal Data 6 Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6 0 - 1023 378
6 Flow Ideal Data 7 Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7 0 - 1023 428
7 Flow Ideal Data 8 Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8 0 - 1023 447
242 Flow Calib. Fan Duty (Not Memorized)
0 Flow Calib Fan Duty 1 Flow Sensor Calibration Duty No.1 [%] 0 - 100 31
1 Flow Calib Fan Duty 2 Flow Sensor Calibration Duty No.2 [%] 0 - 100 36
2 Flow Calib Fan Duty 3 Flow Sensor Calibration Duty No.3 [%] 0 - 100 42
3 Flow Calib Fan Duty 4 Flow Sensor Calibration Duty No.4 [%] 0 - 100 48
4 Flow Calib Fan Duty 5 Flow Sensor Calibration Duty No.5 [%] 0 - 100 54
5 Flow Calib Fan Duty 6 Flow Sensor Calibration Duty No.6 [%] 0 - 100 60
6 Flow Calib Fan Duty 7 Flow Sensor Calibration Duty No.7 [%] 0 - 100 80
7 Flow Calib Fan Duty 8 Flow Sensor Calibration Duty No.8 [%] 0 - 100 100
243 Flow Calib Effective Difference (Not Memorized)
0 Flow Calib Effective Diff 1 Flow Sensor Calibration Range Diff No.1 [ADC] 0 - 1023 250
1 Flow Calib Effective Diff 2 Flow Sensor Calibration Range Diff No.2 [ADC] 0 - 1023 250
2 Flow Calib Effective Diff 3 Flow Sensor Calibration Range Diff No.3 [ADC] 0 - 1023 250
3 Flow Calib Effective Diff 4 Flow Sensor Calibration Range Diff No.4 [ADC] 0 - 1023 250
4 Flow Calib Effective Diff 5 Flow Sensor Calibration Range Diff No.5 [ADC] 0 - 1023 250
5 Flow Calib Effective Diff 6 Flow Sensor Calibration Range Diff No.6 [ADC] 0 - 1023 250
6 Flow Calib Effective Diff 7 Flow Sensor Calibration Range Diff No.7 [ADC] 0 - 1023 250
7 Flow Calib Effective Diff 8 Flow Sensor Calibration Range Diff No.8 [ADC] 0 - 1023 250
244 Flow Clog Threshold (Not Memorized )
0 Flow Clog Threshold 1 Flow Sensor Clogged Threshold No.1[ADC] 0 - 1023 36
1 Flow Clog Threshold 2 Flow Sensor Clogged Threshold No.2[ADC] 0 - 1023 57
2 Flow Clog Threshold 3 Flow Sensor Clogged Threshold No.3 [ADC] 0 - 1023 75
3 Flow Clog Threshold 4 Flow Sensor Clogged Threshold No.4[ADC] 0 - 1023 92
4 Flow Clog Threshold 5 Flow Sensor Clogged Threshold No.5 [ADC] 0 - 1023 108
5 Flow Clog Threshold 6 Flow Sensor Clogged Threshold No.6[ADC] 0 - 1023 121
6 Flow Clog Threshold 7 Flow Sensor Clogged Threshold No.7[ADC] 0 - 1023 153