-7-
Check number of lamp to be replaced on Lamp Status Display.
Loosen 3 screws on Lamp Cover and remove Lamp Cover.
(See right figure.)
1
3
Loosen 2 screws and pull out Lamp Assembly to be replaced
by grasping handle.
4
Turn off a projector and disconnect AC Power Cord. Allow a
projector to cool for at least 45 minutes.
2
Replace Lamp Assembly with a new one and tighten 2 screws.
Make sure that Lamp Assembly is set properly
6
Follow these steps to replace lamp assembly.
Replace Lamp Cover and tighten 3 screws.
5
7
8
Connect AC Power Cord to a projector and turn projector on.
Reset Lamp Replacement Counter. (Refer to section "Lamp
Counter Reset".)
NOTE : Do not reset LAMP REPLACEMENT COUNTER
when lamp is not replaced.
CAUTION : DO NOT OPERATE A PROJECTOR WHILE ANY OF LAMPS IS REMOVED. IT MAY
RESULT IN MALFUNCTIONS, FIRE HAZARD, OR OTHER ACCIDENTS.
SCREWS
LAMP
COVER
SCREWS
ORDER REPLA
CEMENT LAMP
Replacement Lamp Type No. : POA-LMP39
Lamp Service Parts No. : 610 292 4848
Make sure which number of lamp needs to be
replaced on Lamp Status Display.
Figure shows case of replacing LAMP 2.
LAMP 1
LAMP 2
NO
TES ON LAMP REPLACEMENT
To maintain quality of picture (better balance of color and brightness in entire screen), we recommend replacing
all 2 lamps at a time.
CAUTION
Do not drop a lamp assembly or touch a glass
bulb! Glass can shatter and may cause injury.
CAUTION
For continued safety, replace with a lamp
assembly of same type.
Allow a projector to cool for at least 45
minutes before you open Lamp Cover. Inside
of a projector can become very hot.
Lamp Replacement