-48-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
1 Fan2 Initial Volt
Fan Start Voltage(0.1V)
55 0-255
2 Fan3 Initial Volt 55 0-255
4 Fan1 Cooling Speed Fan Voltage at Power Off (0.1V) 130 0-255
5 Fan2 Cooling Speed 130 0-255
6 Fan3 Cooling Speed 130 0-255
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
2 1-15
9 Cooling Time L2
Cooling Time stting at Fan Mode L2 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3 1-15
11
OnStart Cooling Start
Threshold
38 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group
257
Fan Dimmer Setting
0
Dimmer Average Chech
Period
Dimmer Average measurement Time
(0:10sec. 1:30sec. 2:60 sec. 90:
sec...10:30sec.)
0 0-10
1 Dimmer Average Dimmer Average Value (Read only) -
2 Last Voltage Difference -
3 Voltage Difference Goal -
Group
260
Auto Calibration(Common)*Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when
changiing the Value (PC White
100%)
1 Loop Count
Maximum Execution Times
(OFFSET->GAIN)
10 1 - 30
2 Auto Status
Result of Auto-Calibration (Last
Memory)
0 0 / 1 / 9
0: OK, 1: Adjusting,9: Error *
ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group
261
Auto Calibration (RGB)
0 OFFSET AREA H START
Black Level Acquiring Area H-Start
Position
975 0 - 1000
1 OFFSET AREA V START
Black Level Acquiring Area V-Start
Position
500 0 - 1000
2 GAIN AREA H START
White Level Acquiring Area H-Start
Position
25 0 - 1000
3 GAIN AREA V START
White Level Acquiring Area V-Start
Position
500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT
Black/White Level Acquiring Area
Height
9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1-255
Group
262
Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0-1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0-1000
2 Cb Imange Area Start X Cb Acquiring Area H-Start Position 500 0-1000
3 Cb Imange Area Start Y Cb Acquiring Area V-Start Position 200 0-1000
4 Cr Imange Area Start X Cr Acquiring Area H-Start Position 500 0-1000
5 Cr Imange Area Start Y Cr Acquiring Area V-Start Position 200 0-1000
6 Image Area H Width Image Level Acquiring Area 8 0-4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0-4095
8 Y Target Level Target Value of Y Level Adj. 217 0-255
9 Cb Target Level Target Value of Cb Level Adj. 212 0-255