-33-
Electrical Adjustments
Item No. NAME Device
XGA
Range Description
PC
Component Video
HDTV 480p 480i NTSC PAL
49 NOR_VALU_FAN2_MAX M62398FP 125 FAN2 Control Max at Normal
50 ECO_TEMP_FAN1_MIN PW185B 38 FAN1 Control start temp.at Eco
51 ECO_TEMP_FAN1_MAX PW185B 44 FAN1 Control end temp. at Eco
52 ECOTEMP_FAN2_MIN PW185B 38 0-255 FAN2 Control start temp.at Eco
53 ECO_TEMP_FAN2_MAX PW185B 44 FAN2 Control end temp. at Eco
54 ECO_VALU_FAN1_MIN PW185B 55 FAN1 Control Min at Eco
55 ECO_VALU_FAN1_MAX PW185B 100 FAN1 Control Max at Eco
56 ECO_VALU_FAN2_MIN PW185B 65 0-255 FAN2 Control Min at Eco
57 ECO_VALU_FAN2_MAX PW185B 89 FAN2 Control Max at Eco
58 HINOR_TEMP_FAN1_MIN PW185B 44 FAN1 Control start temp.at Highland Normal
59 HINOR_TEMP_FAN1_MAX PW185B 44 FAN1 Control end temp. at Highland Normal
60 HINOR_TEMP_FAN2_MIN PW185B 44 0-255 FAN2 Control start temp.at Highland Normal
61 HINOR_TEMP_FAN2_MAX PW185B 43 FAN2 Control end temp. at Highland Normal
62 HINOR_VALU_FAN1_MIN M62398FP 115 FAN1 Control Min at Highland Nromal (0:0V, 255:25.5V)
63 HINOR_VALU_FAN1_MAX M62398FP 115 FAN1 Control Max at Highland Normal
64 HINOR_VALU_FAN2_MIN M62398FP 132 0-255 FAN2 Control Min at Highland Normal
65 HINOR_VALU_FAN2_MAX M62398FP 132 FAN2 Control Max at Highland Normal
66 HIECO_TEMP_FAN1_MIN PW185B 44 FAN1 Control start temp.at Highland Eco
67 HIECO_TEMP_FAN1_MAX PW185B 44 FAN1 Control end temp. at Highland Eco
68 HIECOTEMP_FAN2_MIN PW185B 44 0-255 FAN2 Control start temp.at Highland Eco
69 HIECO_TEMP_FAN2_MAX PW185B 44 FAN2 Control end temp. at Highland Eco
70 HIECO_VALU_FAN1_MIN M62398FP 105 FAN1 Control Min at Highland Eco
71 HIECO_VALU_FAN1_MAX M62398FP 105 FAN1 Control Max at Highland Eco
72 HIECO_VALU_FAN2_MIN M62398FP 95 0-255 FAN2 Control Min at Highland Eco
73 HIECO_VALU_FAN2_MAX M62398FP 95 FAN2 Control Max at Highland Eco
74 CLNOR_TEMP_FAN1_MIN PW185B 38 FAN1 Control start temp.at Ceiling Normal
75 ClNOR_TEMP_FAN1_MAX PW185B 49 FAN1 Control end temp. at Ceiling Normal
76 CLNOR_TEMP_FAN2_MIN PW185B 38 0-255 FAN2 Control start temp.at Ceiling Normal
77 CLNOR_TEMP_FAN2_MAX PW185B 49 FAN2 Control end temp. at Ceiling Normal
78 CLNOR_VALU_FAN1_MIN M62398FP 65 FAN1 Control Min at Ceiling Nromal (0:0V, 255:25.5V)
79 CLNOR_VALU_FAN1_MAX M62398FP 110 FAN1 Control Max at Ceiling Normal
80 CLNOR_VALU_FAN2_MIN M62398FP 77 0-255 FAN2 Control Min at Ceiling Normal
81 CLNOR_VALU_FAN2_MAX M62398FP 125 FAN2 Control Max at Ceiling Normal
82 CLECO_TEMP_FAN1_MIN PW185B 38 FAN1 Control start temp.at Ceiling Eco
83 CLECO_TEMP_FAN1_MAX PW185B 50 FAN1 Control end temp. at Ceiling Eco
84 CLECOTEMP_FAN2_MIN PW185B 38 0-255 FAN2 Control start temp.at Ceiling Eco
85 CLECO_TEMP_FAN2_MAX PW185B 50 FAN2 Control end temp. at Ceiling Eco
86 CLECO_VALU_FAN1_MIN M62398FP 55 FAN1 Control Min at Ceiling Eco
87 CLECO_VALU_FAN1_MAX M62398FP 100 FAN1 Control Max at Ceiling Eco
88 CLECO_VALU_FAN2_MIN M62398FP 65 0~255 FAN2 Control Min at Ceiling Eco
89 CLECO_VALU_FAN2_MAX M62398FP 89 FAN2 Control Max at Ceiling Eco
90 FAN_1_AUTO_ADJ PW185B 0 0-1 0: OFF(Manual) 1:ON(Auto)
91 FAN_2_AUTO_ADJ PW185B 0 0-1 0: OFF(Manual) 1:ON(Auto)
92 FACTORY_STD_FAN_VOL_MIN PW185B 55 0-255 For Factory
93 FACTORY_STD_FAN_VOL_MAX PW185B 135 0-255 For Factory
94 FAN1_ADJUST_VOLT_MIN M62398FP 22 For Factory
95 FAN1_ADJUST_VOLT_MAX M62398FP 203 For Factory
96 FAN2_ADJUST_VOLT_MIN M62398FP 22 0~255 For Factory
97 FAN2_ADJUST_VOLT_MAX M62398FP 203 For Factory
98
TEMP_ERROR_DETECT_MAX_
TIMES
5 1-9 Detecting times for Temp Error
99 FAN_1_MIN_VOL_LAMP_DIFF 0 0-20
100 FAN_2_MIN_VOL_LAMP_DIFF 0 0-20
101 LAMP_VOL_BORDER_LINE 70 30-90
102 LAMP_VOL - 0-255 Present Lamp Voltage
103 Dimmer Voltage Change Cycle 3 Change cycle of voltage at Dimmer
104 Dimmer Avarage Check Period 10 Measurement time of Dimmer average
105 Dimmer Voltage Change Rate 1 Voltage change rate ta Dimmer
106 Dimmer Average - Dimmer average
107 Last Voltage Difference - Last voltage difference
108 Voltage Difference Goal - Target voltage difference at Dimmer
Group 200 Auto Calibration
0 Execute Calibration PW185B 0 0 - 255 Auto executiong when value changes
1 Loop Count PW185B 3 1 - 30 Loop times of Auto Calibration
2 OFFSET AREA H START PW185B 25 0 - 4095 Black Level Acquire area H-Start Position
3 OFFSET AREA V START PW185B 500 0 - 4095 Black Level Acquire area V-Start Position
4 GAIN AREA H START PW185B 975 0 - 4095 White Level Acquire area H-Start Position
5 GAIN AREA V START PW185B 500 0 - 4095 White Level Acquire area V-Start Position
6 Image AREA H WIDTH PW185B 13 0 - 4095 Black/White Level Acquire area
7 Image AREA V HIGHT PW185B 9 0 - 4095 Black/White Level Acquire area Height
8 OFFSET target PW185B 1 0 - 127 Target for Black Level Adj.
9 OFFSET torelance PW185B 1 1 - 127 Allowence Range for Black Level Adj
10 GAIN target PW185B 244 0 - 255 Target for White Level Adj.
11 GAIN torelance PW185B 1 1 - 255 Allowence Range for White Level Adj
12 Offset Area Average [ Red ] PW185B 0 0 - 255 Read Only
13 Offset Area Average [ Green ] PW185B 0 0 - 255 Read Only
14 Offset Area Average [ Blue ] PW185B 0 0 - 255 Read Only
15 Gain Area Average [ Red ] PW185B 0 0 - 255 Read Only
16 Gain Area Average [ Green ] PW185B 0 0 - 255 Read Only