Electrical Adjustments
Group/
Item
ITEM NAME FUNCTION INITIAL RANGE NOTE
150 R-DCOffset-P8 0/0 0-511
151 R-DCOffset-P9 0/0 0-511
152 R-DCOffset-P10 0/0 0-511
153 R-DCOffset-P11 0/0 0-511
154 R-DCOffset-P12 0 / 22 0-511
155 G-DCOffset-PGain 0/0 0-255
156 G-DCOffset-P1 0 / 4 0-511
157 G-DCOffset-P2 0/0 0-511
158 G-DCOffset-P3 0/0 0-511
159 G-DCOffset-P4 0/0 0-511
160 G-DCOffset-P5 0/0 0-511
161 G-DCOffset-P6 0/0 0-511
162 G-DCOffset-P7 0/0 0-511
163 G-DCOffset-P8 0/0 0-511
164 G-DCOffset-P9 0/0 0-511
165 G-DCOffset-P10 0/0 0-511
166 G-DCOffset-P11 0/0 0-511
167 G-DCOffset-P12 0 / 22 0-511
168 B-DCOffset-PGain 0/0 0-255
169 B-DCOffset-P1 0 / 4 0-511
170 B-DCOffset-P2 0/0 0-511
171 B-DCOffset-P3 0/0 0-511
172 B-DCOffset-P4 0/0 0-511
173 B-DCOffset-P5 0/0 0-511
174 B-DCOffset-P6 0/0 0-511
175 B-DCOffset-P7 0/0 0-511
176 B-DCOffset-P8 0/0 0-511
177 B-DCOffset-P9 0/0 0-511
178 B-DCOffset-P10 0/0 0-511
179 B-DCOffset-P11 0/0 0-511
180 B-DCOffset-P12 0 / 22 0-511 Scan Direction (Front/Rear)
181 ENBX-R
0
0-127
182 ENBX-G
0
0-127
183 ENBX-B
0
0-127
184 DXOutPos
0
0-1
PLC-XU75
Group 100 Panel Service
0 G-SubGain 512/516/472/472/512/516/472/472 0-1023
PCStandard/PCDynamic/PCReal/PCBlack-
Board/AVStandard/AVDynamic/AVCinema/
AVBlackBoard
1 R-SubGain 512/516/472/530/512/516/472/530 0-1023
2 B-SubGain 512/516/472/472/512/516/472/472 0-1023
3 G-SubBright 0/0/24/16/0/0/24/16 0-1023
PCStandard/PCDynamic/PCReal/PCBlack-
Board/AVStandard/AVDynamic/AVCinema/
AVBlackBoard
4 R-SubBright 0/0/24/16/0/0/24/16 0-1023
5 B-SubBright 0/0/24/16/0/0/24/16 0-1023
6 G-GammaShift 512 / 512 0-1023
PC/AV
 
* 5-0% White Adjustment
Center=512
R] and [B] are linked with [G]
7 R-GammaShift 512 / 512 0-1023 *White Balance Adjustment
8 B-GammaShift 512 / 512 0-1023 *White Balance Adjustment
9 G-ReferH 1023 / 1023 0-1023
[R] and [B] are linked with [G] Scan Direction
(Front/Rear)
10 G-ReferL 380 / 380 0-1023
[R] and [B] are linked with [G] Scan Direction
(Front/Rear)
11 R-ReferH 1023 / 1023 0-1023 Scan Direction (Front/Rear)
12 R-ReferL 380 / 380 0-1023 Scan Direction (Front/Rear)
13 B-ReferH 1023 / 1023 0-1023 Scan Direction (Front/Rear)
14 B-ReferL 380 / 380 0-1023 Scan Direction (Front/Rear)
15 DXOutR 237 0-1023
16 DXOutG 237 0-1023
17 DXOutB 237 0-1023
18 H_Change_Pos 3 0-256
19 SH_Base 273 0-4095
20 NRG_Pos 62 0-128
21 NRG_Width 53 0-255
22 OSD_Pos 2 0-3
23 OSD_Ptn 0 0-7
24 GammaCtrl 1 0-1
25 REF_GatePos 5 0-1023