- 20 -
Mechanical disassemblies
5
Main PWB shield plata(top) removal.
1. Remove the 9 screws-A(M3x6), remove the screw-B(M3x10) and remove the Shield plate
(Main board-top) .
6
Main PWB removal.
1. Remove the 3 screws (M3x6), remove the Main board and remove the Shield plate (Main board-BTM).
Shield plate
(Main board TOP)
Shield plate
(Main board BTM)
Main board
A
B
A
A
A
A
A
A
A
A
Caoution;
Be carefull do not damage the
connector
Heat sink sheet
Caoution;
Do not lose the heat sink sheet.