No. Adjustment Item Initial Value Range Input source / Description
19 Fan4 Min Limit 30 30 - 145
20 Fan5 Min Limit 67 1 - 510
21 Fan1 Max Limit 138 30 - 145
22 Fan2 Max Limit 138 30 - 145
23 Fan3 Max Limit 138 30 - 145
24 Fan4 Max Limit 138 30 - 145
25 Fan5 Max Limit 510 1 - 510
26 Fan1 Min Rpm 105 0 - 4500
27 Fan2 Min Rpm 510 0 - 6510
28 Fan3 Min Rpm 105 0 - 4500
29 Fan4 Min Rpm 510 0 - 6510
30 Fan5 Min Rpm 300 0 - 6510
31 Fan1 Max Rpm 4500 510 - 4500
32 Fan2 Max Rpm 6510 510 - 6510
33 Fan3 Max Rpm 4500 510 - 4500
34 Fan4 Max Rpm 6510 510 - 6510
35 Fan5 Max Rpm 6510 510 - 6510
Norm/Celing/Highland/Focus
36 Normal Fan1 Min 1380/1380/1545/1545 510 - 4500
Normal_Temp.-Min
37 Normal Fan2 Min 2220/2220/3420/- 510 - 6510
38 Normal Fan3 Min 1905/1905/2100/2100 510 - 4500
39 Normal Fan4 Min 2595/2595/3180/5115 510 - 6510
40 Normal Fan5 Min 1755/1755/1860/3165 510 - 6510
41 Normal Fan1 Max 1470/1470/1710/1710 510 - 4500
Normal_Temp.-Max
42 Normal Fan2 Max 2460/2460/3630/- 510 - 6510
43 Normal Fan3 Max 1905/1905/2100/2100 510 - 4500
44 Normal Fan4 Max 5115/5115/55115/5115 510 - 6510
45 Normal Fan5 Max 3165/3165/3165/3165 510 - 6510
46 Normal TempA Low 28/28/27/- -5 - 100 Normal_Temp. -sensor A_Control_Start-temp.
47 Normal TempA High 36/36/35/- -5 - 100 Normal_Temp. -sensor A_Control_End-temp.
48 Normal TempB Low 49/49/52/- -5 - 100 Normal_Temp. -sensor B_Control_Start-temp.
49 Normal TempB High 54/54/57/- -5 - 100 Normal_Temp. -sensor B_Control_End-temp.
50 Normal TempC Low 46/46/47/- -5 - 100 Normal_Temp. -sensor C_Control_Start-temp.
51 Normal TempC High 52/52/51/- -5 - 100 Normal_Temp. -sensor C_Control_End-temp.
52 Normal TempA Error 44/44/41/- -5 - 100 Normal_Temp. -sensor A_Shutdown-temp.
53 Normal TempB Error 58/58/62/- -5 - 100 Normal_Temp. -sensor B_Shutdown-temp.
54 Normal TempC Error 57/57/55/- -5 - 100 Normal_Temp. -sensor C_Shutdown-temp.
55 Normal TempB-A Error 33/33/40/- 0 - 100 Normal_Temp. -sensor (B-A)_Shutdown-temp.
56 Normal TempC-A Error 26/26/40/- 0 - 100 Normal_Temp. -sensor (C-A)_Shutdown-temp.
57 Eco Fan1 Min 750/750/1110/1110 510 - 4500
Eco_Temp.-Min
58 Eco Fan2 Min 1350/1350/1920/- 510 - 6510
59 Eco Fan3 Min 1230/1230/1800/1800 510 - 4500
60 Eco Fan4 Min 2010/2010/2265/4050 510 - 6510
61 Eco Fan5 Min 1320/1320/1470/2550 510 - 6510
62 Eco Fan1 Max 1140/1140/1200/1200 510 - 4500
Eco_Temp.-Max
63 Eco Fan2 Max 1485/1485/2010/- 510 - 6510
64 Eco Fan3 Max 1665/1665/1800/1800 510 - 4500
65 Eco Fan4 Max 4050/4050/4050/4050 510 - 6510
66 Eco Fan5 Max 2550/2550/2550/2550 510 - 6510
67 Eco TempA Low 29/29/26 -5 - 100 Ecol_Temp. -sensor A_Control_Start-temp.
68 Eco TempA High 36/36/35 -5 - 100 Ecol_Temp. -sensor A_Control_End-temp.
69 Eco TempB Low 53/53/55 -5 - 100 Ecol_Temp. -sensor B_Control_Start-temp.
70 Eco TempB High 56/56/59 -5 - 100 Ecol_Temp. -sensor B_Control_End-temp.
71 Eco TempC Low 50/50/47 -5 - 100 Ecol_Temp. -sensor C_Control_Start-temp.
72 Eco TempC High 55/55/50 -5 - 100 Ecol_Temp. -sensor C_Control_End-temp.