EasyManua.ls Logo

Sanyo SAP–K303A - 6. ELECTRICAL DATA

Sanyo SAP–K303A
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit SAPK303A
Outdoor Unit SAPC303A
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.330 0.660 12.21 13.2
Power Input kW 0.072 0.146 2.932 3.15
Full Load Conditions Running Amps. A 0.330 0.660 14.51 15.5
Power Input kW 0.072 0.146 3.472 3.69
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.

Related product manuals