EasyManua.ls Logo

Sanyo SAP–K303A - Major Component Specifications

Sanyo SAP–K303A
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
2-2. Major Component Specifications
2-2-1. Indoor Unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No. POWK301A
Controls Microprocessor
Control circuit fuse 250 V – 3.15 A
Remote Control Unit RCS4S4E–G
Type Cross-flow
Q´ty ... Dia. and length mm 1 ... ø100 / L847.4
Fan motor model ... Q´ty KFG4X–31B5P–C ... 1
No. of poles .... rpm (240V, High) 4 ... 1,270
Nominal output W 30
Coil resistance (Ambient temp. 20°C) WHT – BRN : 103.3 WHT – VLT : 32.5
VLT – ORG : 75.5 ORG – YEL : 28.6
YEL – BLK : 18.9 BLK – PNK : 48.0
– :
– :
Safety
Type Thermal protector
devices Operating temp. Open °C 130 ± 8
Close Automatic reclosing
Run capacitor µF 1.0
VAC 440
Type Stepping motor
Model ... Q´ty MP24GA2 ... 2
Rating DC 12 V
Coil resistance (Ambient temp. 20°C) k Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.3
Face area m2 0.214
Heat
Exch. Coil
Flap Motor Fan & Fan Motor
Circuit
Board
Ass´y
Indoor Unit SAPK303A

Related product manuals