install in a sturdy manner to avoid increased
operating noise.
●
install the unit within the maximum elevation
difference (H1, H2, H3, H4) above or below the
outdoor unit and within a total tubing length (L1+L2,
L1+L2+L3, L1+L2+L3+L4) from the outdoor unit as
detailed in Table 1 and Fig. 3a.
Table 1
Max. Allowable Tubing Limit of Total Tubing Limit of Elevation
Model
Length per unit Length (L1+L2), (L1+L2+L3) Difference (H)
(Outdoor unit)
(m) or (L1+L2+L3+L4) (m) (m)
CMRV1923GJH 25 35 (L1+L2) 10
CMRV2433GJH 25 50 (L1+L2+L3) 10
CMRV3143GJH 30 70 (L1+L2+L3+L4) 10
Fig. 3b
For stable operation of the
air conditioner, do not
install wall-mounted type
indoor units less than 1.5 m
from floor level.
(B)
Note: It is not possible to connect the outdoor unit for 2 rooms to indoor unit type 243.