ECO MULTI SYSTEM Unit Specifications
SM830063
I-11
1
1-2. Major component specifications
1. Outdoor Unit
MODEL No. SPW – CR363GVH8 / SPW – CR363GV8
Source 380 - 400 - 415 V / 3 phase / 50Hz
Controller P.C.B. Ass’y CR - CR363GVH / CR - CR363GV
Control circuit fuse 250 V , 3.15 A
Compressor Rotary (Hermetic)
PC (Power Control)
Model … Code No. C-5RN373H8R ... 80838788
Nominal output kW 3.75
Compressor oil (ETHER FV68S) cc 2,000
Coil resistance Ω V - U: 2.83 , U - W: 2.65
(Ambient temperature 25°C) W - V: 2.78
Safety devices
Thermal protector ON / OFF °C 120 ± 5 / 98 ± 11
Microprocessor safety devices Compressor current detection circuit
Compressor discharge gas temperature control
Defective and negative phase detection circuit
Voltage drop detection circuit
Crank case heater V, W 240, 32
High pressure switch ACB - 1TB14W (TUV Approved)
Set pressure ON / OFF kg/cm
2
23.5 ± 2.0 / 31.4
+ 0
Fan (Number … diameter(mm)) Propeller (2 … ø 460)
Fan motor
Model … Nominal output W KFC6T - 91C5P × 2 … 70W × 2
No. of pole … r.p.m. (230 V, High) 6 … 772 r.p.m.
Coil resistance Ω BRN - WHT : 127.3
WHT - VLT : 56.7
VLT - YEL : 15.0
(Ambient temperature 20 °C) YEL - PNK : 7.2
Safety device
Thermal protector ON / OFF °C (79 ± 15) / 130 ± 8
Run capacitor VAC , µF 440 V , 6 µF × 2
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows … fin pitch mm 2 … 2.0
Face area m
2
1.08
Outdoor Unit (A)
– 1. 5