■ 2-Way Air Discharge Semi-Concealed Type
(S Type)
10-3. Before Installing the Ceiling Panel
(1) Adjust the distance between the unit and the
surface of the ceiling (60 mm) using the 2 hex-
agonal nuts as shown in Fig. 10-2 while following
the installation gauge.
(2) Remove the air-intake panel and the air filter from
the ceiling panel as shown in Figs. 10-3 and 10-4.
Never touch or attempt to
move the air-direction louver
by hand or you may damage
the unit. Instead, use the
remote controller if you want
to change the direction of air
flow.
How to remove the air-intake panel (from either
side). (Fig.10-4)
1 Push in. → 2 Slide. → 3 Pull.
→ 4 Remove.
Fig. 10-2
Fig. 10-3
Fig. 10-4
Indoor unit
0143_S_I
Ceiling
60
60
CAUTION
3
1
2
4
0809_S_I
Air-intake panel