3-2
ELECTRICAL ADJUSTMENT PROCEDURES
1. Servo Adjustment
1) PG Adjustment
• Test Equipment
Adjustment And Specification
a) OSCILLOSCOPE
b) PAL TEST TAPE (VHS SP)
MODE
PLAY
Adjustment Procedure
a) Insert the PAL SP Test Tape and play.
Note - Adjust the distance of X, pressing the Tracking(+) or Tracking(-) when the “ATR” is blink after the
PAL SP Test Tape is inserted.
b) Connect the CH1 of the oscilloscope to the H/SW(W5J4, W5J5) and CH2 to the Video Out for the VCR.
c) Trigger the mixed Video Signal of CH2 to the CH1 H/SW(W5J4, W5J5), and then check the distance
(time difference), which is from the selected A(B) Head point of the H/SW(W5J4, W5J5) signal to the
starting point of the vertical synchronized signal, to 6.5H ± 0.5H (416µs, 1H=64.0µs).
CONNECTION
WAVEFORM
V.Out
H/SW(W5J4, W5J5)
VR501 6.5 ± 0.5H
MEASUREMENT POINT ADJUSTMENT POINT SPECIFICATION
V.Out
VR501
H/SW(W5J4,W5J5)
OSCILLOSCOPE
CH1 CH2
V.outH/SW
(W5J4, W5J5)
H/SW
Composite
VIDEO
6.5H(416us)