Questions and Answers

  • A
    Anita Jones DVMAug 14, 2025
    Why does the weight readout on my Sartorius Scales change constantly?
    • S
      Scott RichAug 14, 2025
      The weight readout may change constantly on your Sartorius Scales due to several factors. Unstable ambient conditions may be the cause, so try setting up the balance in another area. Excessive vibration or drafts could also be the reason; access the menu to adapt the balance to the particular weighing environment. Ensure the draft shield is completely closed. Check for any foreign object caught between the pan and the balance housing and remove it. Make sure that the port for the below-balance weighing attachment is covered by fastening the closing plate. Also, consider if the sample has a stable weight, because it may absorb moisture or evaporate.
  • T
    Tamara FletcherAug 17, 2025
    What to do if my Sartorius BA 160 P weight display shows "H"?
    • S
      Stephanie HarrisonAug 17, 2025
      If the weight display on your Sartorius Scales shows "H", it means that the sample exceeds the capacity of the balance. To resolve this, unload the balance.
  • T
    Timothy JonesAug 21, 2025
    Why is the weight readout obviously wrong on my Sartorius Scales?
    • T
      Tyler CookAug 21, 2025
      If the weight readout on your Sartorius Scales is obviously wrong, there are several potential causes. The balance might not be calibrated; in this case you should calibrate it. Alternatively, the balance may not have been tared before weighing, so tare it before weighing. Also, check that the air bubble in the level indicator is within the circle and level the balance if it is not.
  • T
    Thomas WheelerAug 25, 2025
    What to do if Sartorius Scales weight display shows "L" or "Err 54"?
    • T
      Trevor AdkinsAug 26, 2025
      If the weight display on your Sartorius Scales shows "L" or "Err 54", it indicates that the weighing pan, pan support, and/or compensating ring are not in place. Install the weighing pan, pan support (if your model has one), and compensating ring (if applicable to your model).
  • R
    Ricky CollinsAug 28, 2025
    How to fix "Lo Accu" or a flashing weight on Sartorius Scales display?
    • M
      Mary PayneAug 28, 2025
      If your Sartorius Scales display shows "Lo Accu" or a weight flashes, it means the battery voltage is too low. Connect the balance or an external battery pack to line power using the AC adapter.
  • S
    Scott WhiteSep 1, 2025
    What to do if Sartorius BA 160 P weight display briefly displays "Err 02"?
    • L
      Laura LopezSep 2, 2025
      If the weight display on your Sartorius Scales briefly shows "Err 02", it could be due to a couple of reasons. First, the CAL key may not have been pressed when the display indicated zero. Press the tare control and re-press the CAL key. Second, the balance might be loaded, so unload the balance.
  • S
    Shannon HarrisSep 5, 2025
    How to troubleshoot if no segments appear in the weight display of my Sartorius Scales?
    • E
      ecolemanSep 5, 2025
      If no segments appear in the weight display of your Sartorius Scales, it could be due to the following reasons: there is no AC power available, so check the AC power supply. Alternatively, the AC adapter might not be plugged in, so plug in the AC adapter.
  • K
    Kimberly HarveySep 8, 2025
    What to do if the special message does not go out in the weight display of my Sartorius BA 160 P?
    • S
      Shane RiceSep 8, 2025
      If the special message does not disappear from the weight display of your Sartorius Scales, it may be because no key has been pressed since the balance was turned on. Press any key to resolve this.

Summary

Installation Instructions

Startup

Connecting Balance to Power

Steps for starting up models and connecting the balance to AC power.

How to Operate the Balance

Weighing Operations

Covers turning display on/off, self-test, taring, and weight determination.

Calibration Procedure

Step-by-step guide for calibrating the balance to ambient conditions.

Data Interface Usage

How to connect and use the data interface for printing or transferring data.

Balance Operating Menu

Utilities for Data Output

Changing Settings in the Balance Operating Menu

Accessing and Changing Menu Codes

Steps to access the menu and change operating codes.

Reset Function

Troubleshooting Guide

Care and Maintenance

External Calibration Weights

Specifications

Sartorius BA 160 P Specifications

General IconGeneral
Maximum Capacity160 g
Readability0.1 mg
Pan SizeØ 80 mm
Linearity± 0.2 mg
Operating Temperature+10°C to +30°C
DisplayLCD
Repeatability0.1 mg
Stabilization Time≤ 4 seconds
InterfaceRS232
Unitsg, kg, ct, lb, oz, ozt, dwt, mg
Operating Humidity15 % to 80 % relative humidity, non-condensing