EasyManua.ls Logo

Sartorius BA 310 P - User Manual

Sartorius BA 310 P
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Sartorius Basic
Electronic Analytical and precision Balances
Installation and Operating Instructions
98648-002-63

Questions and Answers

  • R
    Roberto SampsonAug 14, 2025
    Why does the weight readout on my Sartorius Scales change constantly?
    • H
      halematthewAug 14, 2025
      The weight readout may change constantly on your Sartorius Scales due to several factors. Unstable ambient conditions may be the cause, so try setting up the balance in another area. Excessive vibration or drafts could also be the reason; access the menu to adapt the balance to the particular weighing environment. Ensure the draft shield is completely closed. Check for any foreign object caught between the pan and the balance housing and remove it. Make sure that the port for the below-balance weighing attachment is covered by fastening the closing plate. Also, consider if the sample has a stable weight, because it may absorb moisture or evaporate.
  • E
    edward46Aug 17, 2025
    What to do if my Sartorius BA 310 P Scales weight display shows "H"?
    • E
      elliottianAug 17, 2025
      If the weight display on your Sartorius Scales shows "H", it means that the sample exceeds the capacity of the balance. To resolve this, unload the balance.
  • E
    Erik PattersonAug 21, 2025
    Why is the weight readout obviously wrong on my Sartorius BA 310 P Scales?
    • D
      Dr. Heather VasquezAug 21, 2025
      If the weight readout on your Sartorius Scales is obviously wrong, there are several potential causes. The balance might not be calibrated; in this case you should calibrate it. Alternatively, the balance may not have been tared before weighing, so tare it before weighing. Also, check that the air bubble in the level indicator is within the circle and level the balance if it is not.
  • P
    Paula DavisAug 25, 2025
    What to do if Sartorius Scales weight display shows "L" or "Err 54"?
    • Q
      qsnyderAug 26, 2025
      If the weight display on your Sartorius Scales shows "L" or "Err 54", it indicates that the weighing pan, pan support, and/or compensating ring are not in place. Install the weighing pan, pan support (if your model has one), and compensating ring (if applicable to your model).
  • J
    jevansAug 28, 2025
    How to fix "Lo Accu" or a flashing weight on Sartorius BA 310 P Scales display?
    • J
      Jesse HullAug 28, 2025
      If your Sartorius Scales display shows "Lo Accu" or a weight flashes, it means the battery voltage is too low. Connect the balance or an external battery pack to line power using the AC adapter.
  • M
    Maria CarterSep 1, 2025
    What to do if Sartorius BA 310 P Scales weight display briefly displays "Err 02"?
    • D
      Daniel BeckSep 2, 2025
      If the weight display on your Sartorius Scales briefly shows "Err 02", it could be due to a couple of reasons. First, the CAL key may not have been pressed when the display indicated zero. Press the tare control and re-press the CAL key. Second, the balance might be loaded, so unload the balance.
  • J
    john98Sep 5, 2025
    How to troubleshoot if no segments appear in the weight display of my Sartorius BA 310 P Scales?
    • K
      Kevin ShawSep 5, 2025
      If no segments appear in the weight display of your Sartorius Scales, it could be due to the following reasons: there is no AC power available, so check the AC power supply. Alternatively, the AC adapter might not be plugged in, so plug in the AC adapter.
  • C
    Christopher MarshallSep 9, 2025
    What to do if the special message does not go out in the weight display of my Sartorius BA 310 P?
    • L
      Leonard WarnerSep 9, 2025
      If the special message does not disappear from the weight display of your Sartorius Scales, it may be because no key has been pressed since the balance was turned on. Press any key to resolve this.

Summary

Installation Instructions

Ambient Conditions

Specifies environmental limits for balance operation and handling.

Startup Procedures

Mounting Draft Shield Components

Instructions for assembling the draft shield chamber and base plate on specific balance models.

Installing Weighing Chamber Components

Details on installing various components within the weighing chamber.

Starting Up Balance Models

Procedures for starting up specific Sartorius balance models.

Connecting to Power

AC Adapter Connection and Voltage Selection

Steps for connecting the AC adapter and selecting the correct voltage.

Balance Leveling

Operating the Balance

Core Weighing Operations

Taring for Accurate Weighing

Steps for using the tare function to zero the display for weight determination.

Performing Weight Determination

How to place a sample and read the weight from the display.

Balance Calibration

Calibration Procedure Steps

Step-by-step guide to calibrating the balance using calibration weights.

Handling Calibration Errors

How to address potential error messages during calibration.

Data Interface and Output

Balance Operating Menu

Data Output Utilities

Changing Balance Settings

Resetting Balance Settings

Resetting Menu Code Changes

Procedure to reset all menu code changes back to factory defaults.

Troubleshooting Guide

Display and Message Issues

Solves problems related to weight display segments, "H", "L", or "Err" messages.

Reading and Stability Problems

Addresses issues with constant weight changes or lack of stable readings.

Accuracy and Calibration Issues

Resolves problems with balance accuracy, calibration, taring, and leveling.

Care and Maintenance

Safety Inspection Procedures

Checks to ensure safe operation of the balance and AC adapter.

Sartorius BA 310 P Specifications

General IconGeneral
BrandSartorius
ModelBA 310 P
CategoryScales
LanguageEnglish

Related product manuals