Model LP2200-0CE LP12000P-0CE LP16000S-0CE LP34000P-0CE LP34-0CE
Type isoTEST in conjunction with BD BF BB BD 523 BB BD 523 BB BD 523
Accuracy class* KKKKK
Scale interval, d* g 0.1 0.1/0.2/0.5 0.1 0.1/0.2/0.5 1
Maximum weighing capacity, Max.* g 2,200 3,000/6,000/ 16,000 8,000/16,000/ 34,000
12,200 34,000
Verification scale interval, e* g 0.1 1 1 1 1
Minimum capacity, Min.* g 5 5 5 5 50
Tare range (subtractive) 100% of the max. weighing capacity
Application range according to CD* g 5 – 2,200 5 – 12,000 5 – 16,000 5 – 34,000 5 – 34,000
Response time (average) s 1 1 1.5 1.5 1
Allowable operating temperature range +10 ... +30°C (50°F ... 86°F)
Selectable weight units Grams, kilograms Grams, kilograms Kilograms
Pan size mm 218 x 200 307 x 417
Dimensions (W x D x H) mm 240 x 360 x 86 307 x 538 x 121
Net weight, approx. kg 6.5 6.5 13.8 13.8 13.8
Model LP34001S-0CE LP16001S-0CE LP34001P-0CE LP34000-0CE
Type isoTEST in conjunction BF BF
Accuracy class * KKKK
Scale interval, d* g 0.1 0.1 0.1/0.2/0.5 1
Maximum weighing capacity, Max.* kg 34 16 8/16/34 34
Verification scale interval, e* g 1 1 1 1
Minimum capacity, Min.* g 5 5 5 50
Tare range (subtractive) 100% of the max. weighing capacity
Application range acc. to CD * g 5 – 34,000 5 – 16,000 5 – 34,000 50 – 34,000
Response time (average) s 1.5 1.5 1.5 1
Allowable operating temperature range 0 ... +40 °C (273 ... 313 K, 32 °F ... 104 °F) with the isoCAL function
1
)
Selectable weight units Grams and Grams and Grams and Kilograms and
kilograms kilograms kilograms grams
Pan size mm 300 x 400
Dimensions (W x D x H) mm 313 x 534 x 120
Net weight, approx. kg 16.0
Dust and water protection rating
according to EN 60529
2
) IP44
1
) = With the isoCAL function deactivated, the verified balance can only be used within the limited temperature range (can only be modified
by the Sartorius Service Center):
For balances of accuracy class k: +15°C to +25°C (59°F to 77°F)
For balances of accuracy class K: +10°C to +30°C (50°F to 86°F)
2
) = specially protected dust-tight and washdown-resistant AC adapter; see the section on “Accessories”