26
Anti-freeze protection
This function is turned off by default. You can turn it on in the advanced thermostat settings.
The function makes sure, that when the room temperature falls below 5°C, the thermostat sends an order to the
receiver to turn on the heating (turn on the boiler, pump,…) and it stays on until the room temperature reaches 8°C.
When this function is turned on, display shows icon 9.
Possible errors
- If the thermostat sensor malfunctions, the display will show “roomERR".
- If you think the temperature displayed on the thermostat is wrong, you can adjust it in the advanced thermostat
settings in the “temperature display correction”.
- If the receiver is not reacting to any thermostat orders, turn off both of the devices and turn them back on. If the error
still stays, repeat the pairing procedure. If nothing helps, call your local shop or the service company (email or phone).
Heating program schedules
The thermostat has an option of using heating program schedules. Possible programs are:
- seven days (every day has its own program),
- 5 + 2 days (monday – friday, weekend),
- 5 + 1 + 1 (monday – friday, saturday, sunday)
and 4 or 6 daily switches. This means that you can set for each day or days 4 or 6 different temperature at different
hours.
By default the heating program schedule is turned OFF and you can only set constant, permanent temperature – same
as hold mode. You can turn it on in advanced thermostat settings where you can set at which days the programs run
and how many daily switches occur. When the heating program schedules are turned on, the default schedules are
set. You can take a look at its values in the next pages and of course you can set the temperatures, switches to your
linking’s in program editing mode.