Maintenance Schedule (General)
Verification
Frequency
(Commercial/
Exterior)
Frequency
(Residential)
Verify correct operation of the phone (where
applicable).
Every 6
months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Verify the following:
General operation of the lift
Operation of the underpan sensors
Operation of the emergency stop
Operation of the door and gate lock
contacts. The lift should not run unless
the door or gate is closed and locked.
Every 6
months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Verify the door lock operation:
The lift is operational when the door is
locked
The lift is NOT operational when the
Normal:
door is open at a landing
Every Year
Insert the lock key to manually unlock
Every 6
Heavy:
the door and ensure the following:
months
Every Year
- The lift is NOT operational when
Excessive:
the door is manually unlocked
Every 6 months
with the key
- The key cannot be removed
from the lock
Verify that all hardware is tightened.
Every 6
months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months