17
Maintenance Schedule (General)
Verification
Frequency
(Commercial/
Exterior)
Frequency
(Residential)
Verify correct operation of the phone (where
applicable).
Every 6
months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Verify the following:
• General operation of the lift
• Operation of the underpan sensors
• Operation of the emergency stop
• Operation of the door and gate lock
contacts. The lift should not run unless
the door or gate is closed and locked.
Every 6
months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Verify the door lock operation:
• The lift is operational when the door is
locked
• The lift is NOT operational when the
Normal:
door is open at a landing
Every Year
• Insert the lock key to manually unlock
Every 6
Heavy:
the door and ensure the following:
months
Every Year
- The lift is NOT operational when
Excessive:
the door is manually unlocked
Every 6 months
with the key
- The key cannot be removed
from the lock
Verify that all hardware is tightened.
Every 6
months
Normal:
Every Year
Heavy:
Every Year
Excessive:
Every 6 months
Part No. 000609, 30-m01-2024 Multilift Owner’s Manual