A/D Conversion Rate | 100 Hz |
---|---|
Power Supply | 24 VDC |
Protocol | Modbus RTU |
Output | Analog, Digital |
Supply Voltage | 24 VDC |
Protection Class | IP65 |
Operating Temperature | -10°C to +40°C |
Load cell excitation | 10 VDC |
Number of load cells | Up to 8 (350 ohm) |
Communication Interface | RS232, RS485 |
Shows display sequence during startup, including software version and unit type.
Explains the auto zero feature at startup and its configuration.
How to put the IPE50 into standby or turn it off.
Explains the meaning of various LED indicators on the front panel.
Details the functions and operations of each scale key.
Specifies conditions for optimal indicator and platform installation.
Covers load cell cabling, junction boxes, screening, and protection.
Addresses grounding, ferrite rings, and explosion risk prevention.
Illustrates the system configuration and parameter flow.
Procedure to enter and exit the scale's setup menu.
Configuring the device type and number of channels for sensors.
Setting decimal points and units of measure for display.
Setting the smallest division for measurements.
Setting the maximum capacity for one or two weighing ranges.
Step-by-step guide to setting calibration points (zero and weights).
Alternative calibration using theoretical values instead of actual load.
Entering loadcell signal (mV/V) and its capacity.
Entering the system's dead load value (e.g., empty silo weight).
Calibrating the unit using a known weight applied to the system.
Details common error messages and their potential causes or solutions.
Explains 4-wire and 6-wire loadcell connections to the unit.
Shows wiring for sensors, relay contacts, and communication ports.
Details analog output configurations and COM port settings.
Illustrates the wiring and connections for the Profibus interface.
Specifications for the 24 Vdc power supply unit.
Explains jumper settings for COM ports and trade-approved mode.
Details configuration for COM1 (RS485/RS232) and COM2 (RS232).
Wiring and specifications for static relay outputs.
Wiring and specifications for opto-insulated input terminals.
Setting the analog output type (0/10V or 4/20mA).
Details 4-wire and 6-wire load cell connections for DIN/XLI models.
Diagram showing terminal assignments for DIN/XLI models.
Configuration of CAL jumper and analog output connections.
Power supply specifications for the IPE50 XLI model.
Pin assignments for connecting sensors to the unit.
Settings for RS485 and RS232 serial ports.
Wiring details for relay contacts and opto-insulated inputs.
Details on current (4/20mA) and voltage (0/10V) output capabilities.
Details on connecting multiple units and termination resistors.
Guidance on using bias resistors for signal integrity issues.