HC1000 Family Environment and Power Specifications
HC1200/1250 Operating
Environment
Operating Air Temperature
5°C - 35°C (41°F - 95°F)
Non-Operating Air Temperature
-40°C - 70°C (-40°F - 158°F)
Operating Humidity
8% - 90% (non-condensing)
Non-Operating Humidity
5% - 95% (non-condensing)
HC1250D(F) Operating
Environment
Operating Air Temperature
10 °C - 35 °C (50 °F - 95 °F)
Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1
°C for every 300-m (984-ft) increase in altitude.
Non-Operating Air Temperature
5 °C - 45 °C (41 °F - 113 °F)
Storage Air Temperature
-40 °C - +60 °C (-40 °F - 140 °F)
Operating Humidity
8% - 80% (non-condensing)
21 °C (70 °F) Max Dew Point
Storage Humidity
8% - 90% (non-condensing)
HC1200 Power
Idle
Load
Startup
Staging
Watts
138.4
204
147
37.1
Amps
1.2
1.804
1.199
0.307
kVA
0.1384
0.204
0.147
0.0371
BTU/hr
472.22
696.05
501.56
126.59
Test Voltage
121.1
120.6
120.9
121.2
HC1250 Power
Idle
Load
Startup
Staging
Watts
142.7
204
161.3
37.5
Amps
1.18
1.81
1.334
0.309
kVA
0.1427
0.204
0.1613
0.0375
BTU/hr
486.89
696.05
550.36
127.95
Test Voltage
121.1
120.6
120.9
121.2
©