Technical data
OPM 300 en-GB 125
© Scania CV AB 2020, Sweden
Intake system
Cooling system
Fuel system
Electrical system
Permissible pressure drop in the intake system with cleaned or new filter
(mbar/psi)
30/0.44
Permissible pressure drop in the intake system with blocked (dirty) filter
(mbar/psi)
65/0.94
Coolant volume, excluding radiator (dm
3
/US gallon)
DC16 084/384A 26/6.9
Other engine types 24/6.3
Coolant volume including 1.5 m
2
Radiator (dm
3
/US gallon)
DC16 084/384A 70/18.5
Other engine types 68/18.0
Coolant volume including 1,6 m
2
Radiator (dm
3
/US gallon)
DC16 314A/320A 40/10.6
Coolant temperature (°C/°F) 90-95/194-203
Number of thermostats 1
Thermostat opening temperature (°C/°F) 80/176 and 87/189
Injection system XPI (Extra High Pressure In-
jection)
Engine management system EMS
Fuel filter Paper filter from Scania
Water separating prefilter Paper filter from Scania
Type 1-pin, 24 V, DC
Starter motor, standard equipment 1-pin, 24 V, 6 kW
Alternator, standard equipment 1-pin, 28 V, 100 A