Renewing the reductant filter
1. Wipe clean around the filter housing to pre-
vent impurities from penetrating it.
2. Remove the filter housing. Use a 46 mm
socket.
WARNING!
There may be a lot of reductant in the filter hous-
ing and it may spill out. Wear protective gloves.
IMPORTANT!
Always rinse away reductant spillage on connec-
tions and other parts with lukewarm water to pre-
vent corrosion. If reductant seeps into electrical
connections or electrical cables, these must be
renewed.
3. Remove the sealing diaphragm.
4. Remove the old reductant filter and fit a new
one.
1
3
4
5
6
2
372 124
1. Pump
2. Filter
3. Sealing diaphragm
4. O-ring
5. Antifreeze
6. Filter housing