04.08.2017 Operation Manual MAM - 890 V1.0
-
18
-
6 Alarm Function
6.1 Monitor text
6.1.1 Air filter alarm
1. Use switching signal to detect alarm
The monitor displays AIR FILTER BLOCK by checking air filter differential pressure switch
2. Set AIR filter max. time
The monitor displays AIR LIFE END when the run time of air filter exhausts
6.1.2 Oil filter alarm
1. Use switching signal to detect alarm
The monitor displays OIL FILTER BLOCK by checking oil filter differential pressure switch
2. Set OIL filter max. time
The monitor displays OIL LIFE END when the run time of the oil filter exhausts
6.1.3 O/A alarm
1. Use switching signal to detect alarm
The monitor displays O/A BLOCK by checking O/A filter differential pressure switch
2. Set O/A max. time
6.1.4 Lubricating oil alarm
1. Use switching signal to detect alarm
The monitor displays LUBE LIFE END when run time of lubrication oil exhausts
6.1.5 Grease alarm
1. Use switching signal to detect alarm
The monitor displays GREASE LIFE END when run time of the grease exhausts
6.1.6 Belt alarm
1. Use switching signal to detect alarm
The monitor displays BELT LIOFE END when the run time of Belt exhausts
6.1.7 High discharge air temperature alarm
1. Use switching signal to detect alarm
The monitor displays HIGH TEMPERATURE when controller detects the discharge air temperature is
higher than ALARM T set data in MANUFACTORY PARA