BASCA - EN
Version 06 01.2010
Display message Cause Remedy
select product
Flowmeter
No water connection
Defective pump (pump pressure < 7.5 bar)
Brew unit blocked
Water system blocked
Grinder mixture too fine
PCB - flowmeter incorrectly connected
Electrical problem (PCB, ...)
Open the shut-off valve and press the beverage
button again.
Check the brew unit.
Check the grinder mixture.
If the message remains on the display: Contact
a qualified service technician.
select product
over temp. brew water
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Contact a qualified service technician.
select product
over temp. tea
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Contact a qualified service technician.
select product
over temp. steam
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Contact a qualified service technician.
selection locked
heating coffee water
The temperature is 10°C below the program-
med temperature.
Beverage output is blocked!
Wait until the target temperature has been
reached.
If the message remains on the display: Contact
a qualified service technician.
selection locked
heating hot water
The temperature is 10°C below the program-
med temperature.
Beverage output is blocked!
Wait until the target temperature has been
reached.
If the message remains on the display: Contact
a qualified service technician.
selection locked
heating steam
The temperature is 10°C below the program-
med temperature.
Beverages can not be dispensed when the
temperature is below 110°C.
Wait until the target temperature has been
reached.
If the message remains on the display: Contact
a qualified service technician.
select product
timeout coffee heater
The programmed temperature of the coffee wa-
ter boiler was not reached within 4 minutes after
the machine was switched switched on.
Beverage output is blocked!
Switch the machine off and then back on.
If the message remains on the display: Contact
a qualified service technician.
select product
timeout HW heater
The programmed temperature of the hot water
boiler was not reached within 4 minutes after
the machine was switched switched on.
Hot water output is blocked!
Switch the machine off and then back on.
If the message remains on the display: Contact
a qualified service technician.
select product
timeout steam heater
The programmed temperature of the steam
boiler was not reached within 4 minutes after
the machine was switched switched on.
Milk and steam output is blocked!
Switch the machine off and then back on.
If the message remains on the display: Contact
a qualified service technician.
selection locked
coffee sensor def.
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Contact a qualified service technician.
selection locked
HW sensor def.
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Contact a qualified service technician.
selection locked
steam sensor def.
Electrical problem between the sensor and
the PCB.
Temperature sensor defective.
Contact a qualified service technician.
selection locked
brew unit time out
The brew unit motor is not running.
Beverage output is blocked!
Contact a qualified service technician.
selection locked
timeout steam suppl.
The level in the steam boiler was not reached. Contact a qualified service technician.
selection locked
milk system locked
The steam temperature has fallen to 115°C.
Wait until the temperature has been reached again.
If the message remains on the display: Contact
a qualified service technician.