Display message Cause Remedy
select product
Flowmeter
No water connection•
Defective pump (pump pressure < 7.5 bar)•
Brew unit blocked•
Water system blocked•
Grinder mixture too fine•
PCB - flowmeter incorrectly connected•
Electrical problem (PCB, ...)•
Open the shut-off valve and press the beverage ►
button again.
Check the brew unit. ►
Check the grinder mixture. ►
► If the message remains on the display: Contact
a qualified service technician.
select product
over temp. brew water
• Electrical problem between the sensor and
the PCB.
• Temperature sensor defective.
Contact a qualified service technician. ►
select product
over temp. tea
Electrical problem between the sensor and •
the PCB.
Temperature sensor defective.•
Contact a qualified service technician. ►
select product
over temp. steam
• Electrical problem between the sensor and
the PCB.
• Temperature sensor defective.
► Contact a qualified service technician.
selection locked
heating coffee water
The temperature is 10°C below the program-
med temperature.
Beverage output is blocked!
Wait until the target temperature has been ►
reached.
► If the message remains on the display: Contact
a qualified service technician.
selection locked
heating hot water
The temperature is 10°C below the program-
med temperature.
Beverage output is blocked!
Wait until the target temperature has been ►
reached.
► If the message remains on the display: Contact
a qualified service technician.
selection locked
heating steam
The temperature is 10°C below the program-
med temperature.
Beverages can not be dispensed when the
temperature is below 110°C.
Wait until the target temperature has been ►
reached.
► If the message remains on the display: Contact
a qualified service technician.
select product
timeout coffee heater
The programmed temperature of the coffee wa-
ter boiler was not reached within 4 minutes after
the machine was switched switched on.
Beverage output is blocked!
Switch the machine off and then back on. ►
► If the message remains on the display: Contact
a qualified service technician.
select product
timeout HW heater
The programmed temperature of the hot water
boiler was not reached within 4 minutes after
the machine was switched switched on.
Hot water output is blocked!
Switch the machine off and then back on. ►
► If the message remains on the display: Contact
a qualified service technician.
select product
timeout steam heater
The programmed temperature of the steam
boiler was not reached within 4 minutes after
the machine was switched switched on.
Milk and steam output is blocked!
Switch the machine off and then back on. ►
► If the message remains on the display: Contact
a qualified service technician.
selection locked
coffee sensor def.
• Electrical problem between the sensor and
the PCB.
• Temperature sensor defective.
► Contact a qualified service technician.
selection locked
HW sensor def.
• Electrical problem between the sensor and
the PCB.
• Temperature sensor defective.
► Contact a qualified service technician.
selection locked
steam sensor def.
• Electrical problem between the sensor and
the PCB.
• Temperature sensor defective.
► Contact a qualified service technician.
selection locked
brew unit time out
The brew unit motor is not running.
Beverage output is blocked!
► Contact a qualified service technician.
selection locked
timeout steam suppl.
The level in the steam boiler was not reached. ► Contact a qualified service technician.
selection locked
milk system locked
The steam temperature has fallen to 115°C.
Wait until the temperature has been reached again. ►