5.1 Faults
A fault in the power supply system is usually caused by a blown fuse.
Please contact our customer service address if you cannot rectify the fault
using the following table.
If this is not possible, e.g. if you are abroad, you can have the caravan
charging system repaired at a specialist workshop. In this case, you must
ensure that the warranty is not invalidated by incorrect repairs being carried
out. Schaudt GmbH will not accept any liability for damage resulting from
such repairs.
Fault Possible cause Remedy
Caravan battery is not
charged during 230 V
operation
No mains voltage Switch on the automatic
circuit breaker in the
vehicle; check the mains
voltage
Defective caravan char-
ging system
Contact customer service
Caravan battery is not
charged whilst driving
Defective alternator Have the alternator chec-
ked
No voltage applied to
”Ignition ON” input or
permanent plus
Have the fuse and cabling
checked
Check the towing vehicle
plug connection
Defective caravan char-
ging system
Contact customer service
Solar charger is not
working (mains s upply off)
Solar charge regulator not
plugged in
Plug in solar charge
regulator
Defective fuse or cabling Have the fuse and cabling
checked
Solar charge regulator de-
fective
Have solar charge regula-
tor checked
12V supply does not work
in the leisure area
12V main switch is
switched off
12V main switch must be
switched on
Defective fuse or cabling Have the fuse and cabling
checked
Defective caravan char-
ging system
Contact customer service
Caravan charging system
cannot be switched on
from the control panel.
Defective caravan
charging system
Contact customer service
No supply voltage Check the battery or
mains c onnection
LIN bus not ready Contact customer service
Panel defective Contact customer service
Flat vehicle