Instruction Manual for Electrobloc EBL 262-4
6
Date: 08.07.2019 8110265 BA / EN
Fault RemedyPossible cause
Starter battery is not
No mains voltage Switch on the automatic
charged during 230 V
circuit breaker in the
constantly below 13.0 V)
voltage
No power supply Check the fuse (20 A of
supply; D+ signal) and
wiring
Too many consumers are
switched on
Switch off consumers not
required
Defective electrobloc Contact the customer
service department
Living area battery is not
Defective alternator Check the alternator
charged during mobile
No voltage on D+ input Check the fuse and wiring
below 13.0 V)
Defective electrobloc Contact the customer
service department
The living area battery is
overcharged during
mobile operation (battery
voltage constantly above
14.3 V)
Defective alternator Check the alternator
The refrigerator does not
work during mobile
operation
No power supply to the
refrigerator
Check the fuse (20 A of
supply; D+ signal) and
wiring
Defective electrobloc Contact the customer
service department
Defective refrigerator Check the refrigerator
12 V supply does not work
12 V main switch for the
12 V main switch for the
nt
e
v
ng area
v
ng area
attery
s
switched off
v
ng area
attery must
e
switched on
Not all plugs or fuses are
plug in all plugs and fuses
p
ugge
nont
e
electrobloc
correct va
ues
on t
e
electrobloc
e
ect
ve
use or w
r
ng
ec
use an
w
r
ng
Defective electrobloc Contact the customer
service department
Y If the device becomes too hot due to excessive ambient temperature or
lack of ventilation, the charging current is automatically reduced. Nevert-
heless, always prevent the device from overheating.
Y If the automatic shutdown mechanism of the battery monitor is triggered,
fully charge the living area battery.
3.4 Closing down the system
A battery is isolated by switching off the main switch on the IT .../LT ... con-
trol and switch panel and by disconnecting a plug connector.
Y ATTENTION!
Total discharge.
Damage to the living area battery:
F Fully charge the living area battery before and after closing down the
system. (Connect vehicle to the mains with an 80-Ah-battery at least
12 hours and with a 160-Ah-battery at least 24 hours).