Instruction Manual for Electrobloc EBL 262-4
8
Date: 08.07.2019 8110265 BA / EN
4.1 Battery functions
6-cell lead-acid or lead-gel batteries, 55 Ah and above
A battery is isolated as follows:
" Switch off the 12 V main switch on the control and switch panel.
" Disconnect battery terminal
This prevents the living area battery from slowly discharging due to closed
circuit current while the vehicle is not in use.
The switching option provided by the battery selector switch ensures opti-
mum charging of the two battery types, lead-gel and lead-acid.
With LT .... control and switch panel : approx. 4 mA
(depending on the control and switch panel being used) under the following
conditions:
F No mains connection
F Living area battery voltage 12.6 V
F 12 V main switch OFF”
Living area battery
Characteristic charging curve IUoU
Final charge voltage 14.3 V
Charge current 18 A
Voltage for float charge 13.8 V with automatic switch function
Starter battery
Charging current float charge max. 1,5 A
4.2 Additional functions
This relay supplies the refrigerator with power from the living area battery
when the vehicle engine is running and the D+ connection is live.
The power supply to this consumer is automatically interrupted as soon as
the engine starts running (the D+ connection is live in this case). The awning
light can still be used even if the 12 V power supply is switched off.
This feature provides an automatic max. 2 A float charge for the starter bat-
tery when the 230 V mains is connected to the electrobloc.
5 Maintenance
The EBL 262-4 electrobloc is maintenance free.
Clean the electrobloc with a soft, slightly damp cloth and mild detergent. Ne-
ver use spirit, thinners or similar substances. Do not allow liquids to enter
the electrobloc.
No part of this manual may be reproduced, translated or copied without ex-
press written permission.
Suitable batteries
Battery isolation
Battery selector switch
Standby current from
living area battery
(without consumer
currents)
Battery charging via
mains connector
Refrigerator
Awning light
Mains charging of the
starter battery
Cleaning