6 – MAINTENANCE (ROUTINE AND SPECIAL) COD: 150Z24.B.2021
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
34
6. MAINTENANCE (ROUTINE AND SPECIAL)
6.1 Check filter cleanliness
It is very important to inspect filters condition periodically.
In the system there are the following:
1. Mesh filter (strainer).
2. Pump filter (5 micron cartridge filter – blue and white filter housing).
3. Active carbon filter.
In order to keep the filters properly clean, follow the tab illustrated hereby:
Check and clean the
strainer
Visual inspection and washing
Replace the 5 micron
cartridge filters
It depends on the working
conditions and the turbidity of the
sea water. In average conditions
the replacement of the cartridge
is recommended every 80-100
working hours. Once replaced
the filters, it is necessary to
purge the air from the system,
opening for 2-3 minutes the
depressurization valve.
Unscrew the filter housing counter
clockwise by using the specific key
provided
Replace the active carbon
fibre filter
Unscrew the filter housing counter
clockwise by using the specific key
provided