Page #17 background imageLoading...
Page #17 background image
17GB
Storage
m Important!
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Switch
off the compressor and make sure that it is secured
in such a way that it cannot be started up again by
any unauthorized person.
m Important!
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted!
Storage power cord, hose and accessories (Fig. 2)
The power cord can be stored sideways of the com-
pressor.
The air hose can be stored in the tool compartment.
Transport
The unit can be transported with the handle (1) (g.
5).
Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in this
packaging can be reused or recycled. The equipment
and its accessories are made of various types of mate-
rial, such as metal and plastic. Defective components
must be disposed of as special waste. Ask your
dealer or your local council.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
Cleaning, maintenance, and storage
n Important!
Pull out the power plug before doing any cleaning and
maintenance work on the equipment. Risk of injury from
electric shock!
n Important!
Wait until the equipment has cooled down completely!
Risk of burns!
n Important!
Always depressurize the equipment before carrying out any
cleaning and maintenance work! Risk of injury!
Cleaning
Keep the equipment free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or
blow it down with compressed air at low pressure.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaningagents or sol-
vents; these may be aggressive to the plastic parts
in the equipment. Ensure that no water can get into
the interior of the equipment.
You must disconnect the hose and any spraying tools
from the compressor before cleaning. Do not clean
the compressor with water, solvents or the like.
Troubleshooting
Fault Possible cause Remedy
The compressor does
not start.
No supply voltage.
Insuf cient supply voltage.
Outside temperature is too low.
Motor is overheated.
No supply voltage.
Insuf cient supply voltage.
Outside temperature is too low.
Motor is overheated.
The compressor starts
but there is no pressure.
The non-return valve leaks.
The seals are damaged.
The non-return valve leaks.
The seals are damaged.
The compressor starts,
pressure is shown on
the pressure gauge, but
the tools do not start.
The hose connections have a leak.
A quick-lock coupling has a leak.
The hose connections have a leak.
A quick-lock coupling has a leak.