15. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault Possible cause Remedy
Engine will not start
No fuel in the tank. Fill the tank up.
Fuel valve closed. Open the fuel valve.
Air lter dirty. Clean the air lter.
Engine switch is set to “OFF”. Set the engine switch to “ON”.
Recoil starter defective. Repair the recoil starter.
No engine oil. Rell the engine oil.
Spark plug dirty. Clean the spark plug
Engine oil level low. Rell the engine oil.
On/o󰀨 switch for motor operation set
incorrectly.
Set to the correct position
Engine is running loudly/
irregularly
Spark plug dirty Clean/replace the spark plug.
Air lter severely dirty Clean/replace the air lter.
Fuel contaminated/stale Drain and replace the fuel.
Choke lever to “CHOKE”
Turn the choke lever to the “RUN
position
Incorrect fuel - diesel instead of petrol Drain the fuel and ll with the correct fuel
No electrical output Fault in the a.c. power generator
For service under warranty, inform your
representative
Engine will not switch o󰀨 Ignition switch-o󰀨 wire defective
Close the fuel valve and wait until the
engine shuts o󰀨; call customer service