SCHOTT TITRONIC universal - User Manual

SCHOTT TITRONIC universal
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Gebrauchsanleitung Kolbenbürette
TITRONIC
®
universal
Operating Instructions Piston Burette
TITRONIC
®
universal
Mode d'emploi Burette à piston
TITRONIC
®
universal
Manual de instrucciones Bureta de émbolo
TITRONIC
®
universal

Questions and Answers

  • S
    Stephen SmithAug 3, 2025
    What to do if the SCHOTT TITRONIC universal is not titrating or dosing the solution?
    • B
      Brandon CarrollAug 3, 2025
      If your SCHOTT Laboratory Equipment isn't titrating or dosing the solution, several factors could be at play. First, ensure the dosing unit is correctly filled by performing an initial filling. Next, confirm that the dosing unit is securely locked with a quarter rotation in the lower position. Check the hose and titration tip for any bends or obstructions, replacing them if necessary. Also, filter or replace the titration solution if undissolved particles are present, and double-check that the valve hoses are correctly connected. If air bubbles are present in the system, please refer to 'Air bubbles in the dosing system'.
  • K
    Kayla DuncanAug 9, 2025
    Why is the stirrer not working in my SCHOTT TITRONIC universal?
    • S
      Shane WilliamsAug 9, 2025
      If your SCHOTT Laboratory Equipment stirrer isn't working, start by cleaning the connection contacts. Ensure the reagent bottle is adequately filled, topping it up or replacing it as needed. Make sure the hose is immersed deeply enough in the reagent bottle; if not, immerse it further or add more reagents. Verify that the dosing unit is properly latched with a quarter rotation in the lower position. Check that the hose connections are tight, and if the hose has been pulled out of the threaded connection, fasten it fingertight, and consider replacing the hoses and screw connectors. If the valve is defective, replace it.
  • V
    valenzuelatracyAug 15, 2025
    How to fix a dark display and no response from my SCHOTT TITRONIC universal?
    • M
      Martha ChristensenAug 15, 2025
      If the SCHOTT Laboratory Equipment device isn't responding and the display is dark, it might be due to a disturbance in the internal program, possibly from electrostatic charging or mains overvoltage. Try switching the device off, and then switch it on again after 10 seconds. Also, the display contrast might be misadjusted. Use the knurled knob on the right side of the bottom to adjust the contrast.
  • M
    Matthew WoodAug 21, 2025
    What to do if the SCHOTT TITRONIC universal Laboratory Equipment titration tip drips after use?
    • M
      Marcus WilkinsAug 21, 2025
      To resolve dripping from the titration tip of your SCHOTT Laboratory Equipment after use, try setting a longer filling time. This can help eliminate air bubbles in the system that may be causing the dripping.
  • W
    Willie ChaseAug 27, 2025
    How to fix 'rattling' when installing the dosing unit in SCHOTT TITRONIC universal Laboratory Equipment?
    • T
      thomas58Aug 27, 2025
      If the piston rod isn't correctly pulled in when installing the dosing unit on your SCHOTT Laboratory Equipment, causing the device to “rattle”, it may be due to oblique application of the piston rod. Re-apply the piston rod vertically to correct this issue.

Summary

Suppliers Certificate

Properties of the TITRONIC universal Piston Burette

General

Overview of the TITRONIC® universal Piston Burette's capabilities and features.

Dosing and Titration Solutions

Guidelines on suitable solutions and safety rules for handling chemicals.

Declaration of Conformity

Technical Data

Warning and Safety Information

Setting Up and Commissioning

Unpacking and Setup

Procedures for unpacking and preparing the device for use.

Stirrer Installation

Steps for correctly attaching the TM 96 Stirrer to the burette.

Stand Installation

Instructions for mounting the stand rod and holder.

Connecting Peripherals and Power

How to connect accessories and power on the device.

Working with the TITRONIC universal Piston Burette

Keys and Contrast Adjustment

Explanation of device keys and how to adjust display contrast.

Switch-on Image and Filling Time

Understanding the startup screen and setting the filling time.

Language Selection

How to choose the display language for the device.

Rinsing and Initial Filling

Procedure for rinsing the system and filling it with solution.

Filling the Burette

How the burette refills automatically or manually.

Setting Operational Parameters

How to adjust various operational parameters like volume and speed.

Performing Titration

Detailed steps for performing titration using the device.

Performing Dosing

Instructions for executing dosing procedures with the burette.

Incremental Dosing

How to perform incremental dosing and set parameters.

RS-232-C Interfaces and Communication

General RS-232-C Information

Introduction to the RS-232-C interfaces for data communication.

Setting Data Transfer Parameters

How to configure baud rate, parity, data bits, etc.

Device Addressing and Daisy Chaining

How to address devices and connect them in a daisy chain.

RS Communication Command List

Reference for commands used in RS communication.

Dosing Accuracy

Replacing the Dosing Unit

Detaching and Placing Dosing Unit

Step-by-step guide for removing and installing the dosing unit.

Replacing Titration Solution

Procedure for changing the titration solution.

Troubleshooting

Maintenance and Care

Maintenance Intervals

Recommended schedule for checking and maintaining the device.

Maintenance Work Procedures

Details on checks and actions for maintenance.

Handling Interruptions of Use

What to do when the device is not used for extended periods.

Cleaning the Device

Instructions for cleaning the TITRONIC® universal Piston Burette.

Storage, Transportation, and Environment

Accessories and Spare Parts

Order Numbers

SCHOTT TITRONIC universal Specifications

General IconGeneral
ModelTITRONIC universal
CategoryLaboratory Equipment
Product LineTITRONIC
Resolution pH0.01 pH
Measuring range mV-2000 to 2000 mV
Resolution mV0.1
Resolution temperature0.1
Accuracy temperature±0.1 °C
Burette volume10 ml or 20 ml
InterfacesUSB, RS232
ManufacturerSCHOTT