EN
37
Re-insert cover and drawer
►
Tighten the screws on the cover after transportation.
►
Re-insert the filter drawer.
Installation area
Maximum floor load (without socle) in operating
status:
D 200 D 325
2 125 N 2 650 N
In order to ensure the stability of the appliance during
spin drying, the installation area must be firm and
level.
Soft floor coverings, e.g. fitted carpets or coverings
with a foamed material backing are not suitable as an
installation area.
►
Keep the area surrounding the dryer free of dust and
fluff.
Keep machine dimensions in mind
Notice
The machine can be placed with its back against a
wall. The minimum distance between the machine and
the wall or possibly another machine is 50 cm.
79cm
135cm
>50cm
90cm (D 200)
120cm (D 325)
►
Take note of the appliance measurements and the
space required to connect it to an exhaust air duct.
Aligning the appliance
Notice
The machine must be in a vertical position with all
four feet firmly on the floor and it must not wobble.
►
Do not remove the screw feet under any circumstances.
►
Align the appliance with the help of a spirit level on all
sides.