EasyManua.ls Logo

Schumacher EV Series - User Manual

Schumacher EV Series
276 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN
AR
DA
DE
EL
ES
FI
FR
IT
NL
NO
PL
PT
SV
TR
English
Arabic
Danish
German
Greek
Spanish
Finnish
French
Italian
Dutch
Norwegian
Polish
Portuguese
Swedish
Turkish
English
ةيبرعلا
Dansk
Deutsch
Ελληνικά
Español
Suomalainen
Français
Italiano
Nederlands
Norsk
Polski
Português
Svenska
Türkçe
002
020
037
055
074
094
112
130
148
166
184
202
220
238
256
- 1 -
0099002437-00
MODE 3 EV WALL CHARGER
SEV455

Table of Contents

Questions and Answers

  • B
    Brenda RamirezAug 16, 2025
    What to do if my Schumacher EV Battery Charger shows overvoltage?
    • R
      Ricky ColemanAug 16, 2025
      If your Schumacher Battery Charger shows an overvoltage fault, first, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the problem persists, it is recommended to consult a licensed electrician to check the AC supply.
  • S
    Sharon HowardAug 19, 2025
    What to do if my Schumacher EV shows undervoltage?
    • R
      Rebecca WilliamsSep 12, 2025
      If your Schumacher Battery Charger is showing an undervoltage fault, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the fault continues, it is recommended to consult a licensed electrician to check the AC supply.
  • C
    Cassie LucasAug 22, 2025
    What to do if my Schumacher Battery Charger has a ground fault?
    • J
      jakeortizAug 22, 2025
      If your Schumacher Battery Charger is experiencing a ground fault, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the issue continues, it is recommended to consult a licensed electrician to check the ground connection.
  • R
    Riley HancockAug 25, 2025
    What to do if my Schumacher EV shows overcurrent?
    • D
      Diana GonzalezAug 26, 2025
      If your Schumacher Battery Charger is showing an overcurrent fault, unplug the charging gun and then reinsert it into your vehicle’s charging port.
  • D
    Donna PriceAug 28, 2025
    What to do if my Schumacher EV Battery Charger says 'over temperature'?
    • L
      Laura SnowAug 28, 2025
      If your Schumacher Battery Charger displays an 'over temperature' message, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the problem continues, unplug the charging gun and allow the unit to cool down before attempting to charge again.
  • A
    alicia96Aug 31, 2025
    How to troubleshoot no AC power on my Schumacher EV Battery Charger?
    • A
      Amber AtkinsAug 31, 2025
      If your Schumacher Battery Charger has no AC power, check the breaker. It is also recommended to have a licensed electrician connect the charging station to AC power.
  • M
    Michael GonzalezSep 3, 2025
    What to do if my Schumacher EV has leakage?
    • M
      Michael StanleySep 3, 2025
      If your Schumacher Battery Charger experiences a leakage issue, re-power the unit by turning the circuit breaker off and on again. If the fault still exists, please consult a licensed electrician for help or contact our support service.
  • L
    leecarrieSep 6, 2025
    What to do if my Schumacher EV Battery Charger shows a frequency fault?
    • B
      Brittany GarciaSep 6, 2025
      If your Schumacher Battery Charger is showing a frequency fault, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the fault continues, it is recommended to consult a licensed electrician to check the AC supply.
  • E
    Elizabeth RichSep 9, 2025
    What to do if my Schumacher EV Battery Charger has a meter chip fault?
    • T
      Thomas PerezSep 9, 2025
      If your Schumacher Battery Charger is experiencing a meter chip fault, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the issue persists, contact our support service.
  • J
    James SantiagoSep 12, 2025
    What to do if my Schumacher EV Battery Charger has a relay fault?
    • J
      John FosterSep 12, 2025
      If your Schumacher Battery Charger has a relay fault, unplug the charging gun and then reinsert it into your vehicle’s charging port. If the issue continues, contact our support service.

Summary

Important Safety Instructions

Instructions Pertaining to a Risk of Electric Shock

Grounding Instructions

Details the mandatory grounding requirements for safe connection of the EV charger.

Installation Instructions

Electrician Requirements

Specifies that installation and electrical setting changes must be performed by a licensed electrician.

Choosing a Location

Hardwiring the Power Supply Permanently to the Charging Station

Power Off Requirement

Crucial instruction to turn off power before installation to prevent injury or death.

Connecting the Output Cable to the Charging Station

Inserting Output Cable Wires

Guide for feeding and connecting the output cable wires to the correct terminal blocks.

Mounting the Charging Station to the Wall

Final Steps

Electrician Configuration

Tasks for a licensed electrician, including breaker sizing and DIP switch settings.

Set DIP Switches Without CT Coil Installed

Identifying DIP Switches

Locating the 8-position DIP switch selector on the electronic board.

DIP Switch Settings Table

Table showing DIP switch combinations for setting maximum output current and power.

Set DIP Switches With Current Transfer (CT) Coil Installed

CT Coil Functionality

Explains the role of the CT coil as a sensor for Dynamic Power Management.

CT Coil Installation

Guidance on attaching and connecting the CT coil to the main cable and charger.

Connecting CT Coil Cables

Steps for connecting the CT coil's unsheathed and shielded cables to the charger's terminal blocks.

CT Coil Settings

CT Coil Calibration Note

Reminder that correct installation requires calibration of the maximum charge current.

CT DIP Switch Settings Table

Table detailing DIP switch combinations for various CT coil turns ratios and current ratings.

CT Coil Turns Ratio Settings

CT Coil Settings Overview

Comprehensive table detailing DIP switch settings based on CT coil turns ratio and DLM current rating.

Final Reassembly

Operating Instructions

LED Behaviors

Troubleshooting

Power LED Troubleshooting

Solutions for issues related to the Power LED being off, typically indicating no AC power.

Charging Status LED Red Flashes (2-9 Times)

Troubleshooting steps for specific red flashing codes of the Charging Status LED, indicating various faults.

Charging Status LED Red Flash (10 Times)

Schumacher EV Series Specifications

General IconGeneral
BrandSchumacher
ModelEV Series
CategoryBattery Charger
LanguageEnglish

Related product manuals