3 Technical data
3.1 Basic data
Connection data
Designation
MPG-plus
10-12 16–64
Pressure medium Compressed air, compressed air quality
according to ISO 8573-1:7 4 4
Nominal working
pressure [bar]
6
Min. pressure [bar]
without gripping
force maintenance
with gripping force
maintenance
3
-
2.5
4.0
Max. pressure [bar]
without gripping
force maintenance
with gripping force
maintenance
6
-
8.0
6.5
More technical data is included in the catalog data sheet.
Whichever is the latest version.
Ambient conditions and operating conditions
Designation MPG-plus
Ambient temperature [°C]
min.
max.
+5
+90
Protection class IP * 30
Noise emission [dB(A)] ≤ 70
* For use in dirty ambient conditions (e.g. sprayed water, vapors,
abrasion or processing dust) SCHUNK offers corresponding
product options as standard. SCHUNK also offers customized
solutions for special applications in dirty ambient conditions.