Assembly
36
13.00 | MPG-plus | Assembly and operating manual | en | 389216
5.3.8.2 Mounting the FPS-S 13
Size MPG-plus 20 / 25 / 32
For these sizes, the sensor is mounted directly onto the housing.
Ø Position sensor(3) with the circular elevation(1) in the recess in
the housing(2).
Ø Secure sensor with screws(4).
Tightening torque: 10Ncm
Ø Connect the torque sensor system controller and adjust the
sensor, see the Assembly and Operating Manual for the sensor.
Size MPG-plus 40 / 50
For these sizes, a holder must be mounted. This holder is available
from SCHUNK.
Ø Secure holder (1) with screws (2).
Ø Secure sensor(4) with screws (3).
Tightening torque: 10Ncm