33
EN
8
Open partially
(pedestrian
opening)
8-1 10%
This function can adjust the time of
opening partially.
The factory setting is « 8-2 »
8-2 20%
8-3 30%
8-4 40%
8-5 50%
8-6 60%
9 Pre-Flashing
9-0
The flashing light
blinks when the
gate starts to move
The factory setting is « 9-0 »
9-1
The flashing light
blinks 3 seconds
before the gate
starts to move
A
Over current
reverse setting
A-0 Stop
The factory setting is « A-3 » .
The reverse function only operates 3
times and then stops.
If gate reverses, the auto close
function will be cancelled.
A-1 Reverse 1 second
A-2 Reverse 3 seconds
A-3 Reverse to the end
C
Full open remote
switch
(on the remote
control)
C-1 the top left button
The factory setting is « C-1 » .
C-2 the top right button
C-3
the bottom left
button
C-4
the bottom right
button
E
Pedestrian open
remote switch
(on the remote
control)
E-0
No function in
transmitter
The factory setting is « E-2 »
E-1 the top left button
E-2 the top right button
E-3
the bottom left
button
E-3
the bottom right
button
7
Over current
setting
7-0 4A
The function can adjust the running
force of motor to be compatible with
the gate weight.
The factory setting is « 7-1 »
7-1 6A (fault)
7-2 8A
7-3 10A
7-4 12A
7-5 14A
7-6 16A
7-7 18A
7-8 20A
7-9 22A