40Revision 2.EL950 1.3.1074C 18.6
EXACT CHANGE
Sets the coin tube value that will trigger the display to show Please Use Exact Change message. For
example, if Exact Change is set to $5.00, the message will display when the total of coins in the tube, as
counted by the VMC, is at or below $5.00 total.
ALTERNATE RULE
This funcon prevents a vend from occurring, ashes the Please Use Exact Change message and will return
the established credit amount if one or more of the coin tubes are too low to give back the correct change
for the vend. Note: This seng must be OFF if using a bill validator only. If using a bill validator only, prices
must be divisible by the denominaons accepted by the bill validator.
UNCONDITIONAL ACCEPTANCE
Sets the uncondional acceptance value. All cash box coins or bills equal to or less than this set value
will be accepted, even if the changer cannot return an equal amount of change. When set to 0 (zero), all
changer tube coins are accepted. Bills are accepted once there is enough change in the changer to pay back
the bill type. Note: the Uncondional Acceptance set value is adjustable but the maximum value is equal to
the largest denominaon of currency or coin accepted by the changer or validator.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 6 for Password (Advanced Features) Menu Password
3. Enter Password (default 2314) Advanced Features
4. Press 2 for Exact Change Exact Change $--.00 *-Exit 1 Edit
5. Press 1 to edit Exact Change Exact Change (Flashing) *-Exit 1-Edit
6. Use number keys to enter an amount Exact Change (New Seng) *-Exit 1-Edit
7. Press # to save the seng Exact Change (New Seng) *-Exit #-Save
8. Press * two mes to exit 0.00
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 6 for Password (Advanced Features) Menu Password
3. Enter Password (default 2314) Advanced Features
4. Press 2 for Exact Change Exact Change $--.00 *-Exit 1-Edit
5. Press 2 to set Alt Rules Alt Rules (Current Seng) *-Exit 2-Edit
6. Press 2 to toggle ON/OFF (default ON) Alt Rules (Choice Flashing) *-Exit #-Save
7. Press # to save the seng Alt Rules (New Seng) *-Exit 3 Edit
8. Press * two mes to exit 0.00
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 6 for Password (Advanced Features) Menu Password
3. Enter Password (default 2314) Advanced Features
4. Press 3 for Uncondional Acceptance menu Uncond Accept: (Current Seng) *-Exit #-Edit
5. Press 3 then enter value Uncond Accept: (New Seng) * Exit #-Save
6. Press # to save the seng Uncond Accept: (New Seng) *-Exit #-Save
7. Press * two mes to exit 0.00