46Revision 2.EL950 1.3.1074C 18.6
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 9 for Selecon motor test menu Selecon: (First Selecon) *-Stop
3. Press * to exit to Sales Mode 0.00
Relays System Logs*
Vigilant Vend Sensor On Door
Drop Bias Seng* Manual Defrost

  
VMC Sengs Reset VMC has been reset to factory default. If a soware upgrade has just been performed, the
VMC has been reset to default sengs. Change your
prices and other sengs as required. Cycle power and
verify your changes and any error messages.
VMC Door Switch Door switch is seen as open for greater than the allowed
me.
Check the door switch for correct operaon. Check
door wire harness.
VMC Scale Factor There is a conict with one or more MDB seng from the
installed MDB devices.
Review manuals and sengs for installed MDB devices
to make sure they are compable.
VMC Selecon SW A keypad selecon buon is stuck in the depressed
posion.
Determine reason why keypad buon is stuck and
repair.
VMC Low AC The incoming AC power is lower than required to properly
run your vending machine.
Determine why voltage is low. Remove any voltage
reducing devices not authorized by the vending
machine manufacturer.
VMC RAM Checksum A RAM checksum error indicates that accounng data or a
VMC seng was in error. The VMC will use a backup copy
of the data where possible.
Check the VMC sengs and accountability data for
correctness. Cycle power to the vending machine and
recheck error messages.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 0 for Test Modes Test Modes
3. to test relays; then press 1-6 to test each relay. Press 2 for vend sensor alignment test.
 then password 2314 for log. NOTE: Do not use unless requested by trained personnel.
 and toggle ON/OFF to show errors when door opens.
 for Manual Defrost, which will enable you to set a manual defrost period for the machine.
NOTE: Do not use unless requested by trained personnel.
Test Modes 1 through 5
4. Press * to exit to Sales Mode 0.00
SELECTION ALL
This funcon tests all motors in sequence automacally. To stop the test, press * to exit. NOTE: All
selecons should be empty prior to performing this test.
TEST MODES
This menu contains diagnosc tests and sengs for the following systems: