EasyManua.ls Logo

Seaga INF4C - Troubleshooting Motor Errors; Refrigerated Model Sensor Error Troubleshooting; Troubleshooting Vend Sensor Errors; Troubleshooting Coin Changer Errors

Seaga INF4C
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47Revision 2.EL950 1.3.1074C 18.6

  
Motor [Number] Open The motor indicated or harness to that motor
has an open electrical connecon.
Check the motor and motor harness for open connecons.
Test vend motor. Replace if necessary.
Motor [Number] Short The motor or harness has an electrical short. Check motor and motor harness for short. Replace if
necessary.
Motor [Number] Home Sns The motor home switch was not detected
while the motor was in operaon. This may
also indicate a motor jam condion.
Check motor type service mode seng, motor, motor switch
and then spiral for blockage. Test vend selecon motor if
necessary.
Motor [Number] Jam A motor jam has been detected. Check motor and spiral for blockage.
Motor [Number] Errors One or more motor errors have been
detected.
Test vend selecon motor and review informaon on motor
open, short, home switch and jam condions.
Motor Under Voltage The detected motor voltage is not high
enough to run the selecon motors.
Test vend selecon motor for correct operaon. Replace
motor. Replace VMC.

Error Message Descripon Possible Soluons
Refrig Sensor # Open A temperature sensor or harness is considered to have an
open electrical connecon. Where # is the sensor number.
Check sensor and sensor harness for open
connecons. Check for sensor readings. Replace
sensor if necessary.
Refrig Sensor # Short A temperature sensor or harness is considered to have an
electrical short. Where # is the sensor number.
Check sensor and sensor harness for shorted
connecons. Replace if necessary.
Refrig Health Safety The cabinet temperature and me limit sengs have been
exceeded.
Check sensor readings and sensor harness for
shorted connecons. Check for sensor readings.
Replace sensor if necessary.

Error Message Descripon Possible Soluons
Opcal Sensor Error The vend sensor is blocked, out of alignment
or not detected.
Check sensor and sensor harness for open connecons. Check for
sensor readings. Replace sensor if necessary.

  
Coin Mech Comm VMC does not have communicaon with the coin changer. Check MDB Harness to changer. Check for power
on changer. See changer service manual.
Coin Mech Tube Sns The coin changer has reported a tube sensor error. See changer service manual.
Coin Mech Inlet The coin changer has reported an acceptor blockage. Check changer tubes. See changer service manual.
Coin Mech Tube Jam The coin changer has reported a tube payout error. Check changer tubes. See changer service manual.
Coin Mech ROM The coin changer has reported a program memory error. See changer service manual.
Coin Mech Excess Esc The coin changer has reported that a large number of coin
escrow requests have occurred.
Check changer escrow lever posion.
Coin Mech Coin Jam The coin changer has reported that a coin is jammed in the
coin path.
Check changer coin path. See changer service
manual.
Coin Mech Low Accept The VMC has seen a low acceptance rate on coins. Review inserted coins. See changer service manual.
Coin Mech Accpt Disc The coin changer has reported that the coin validaon
acceptor is disconnected.
Re-connect the coin changers acceptor. See
changer service manual.
Coin Mech Route Err The coin changer reported that a coin did not follow the
correct path.
Check changer coin path. See changer service
manual.

Related product manuals