47Revision 2.EL950 1.3.1074C 18.6
Motor [Number] Open The motor indicated or harness to that motor
has an open electrical connecon.
Check the motor and motor harness for open connecons.
Test vend motor. Replace if necessary.
Motor [Number] Short The motor or harness has an electrical short. Check motor and motor harness for short. Replace if
necessary.
Motor [Number] Home Sns The motor home switch was not detected
while the motor was in operaon. This may
also indicate a motor jam condion.
Check motor type service mode seng, motor, motor switch
and then spiral for blockage. Test vend selecon motor if
necessary.
Motor [Number] Jam A motor jam has been detected. Check motor and spiral for blockage.
Motor [Number] Errors One or more motor errors have been
detected.
Test vend selecon motor and review informaon on motor
open, short, home switch and jam condions.
Motor Under Voltage The detected motor voltage is not high
enough to run the selecon motors.
Test vend selecon motor for correct operaon. Replace
motor. Replace VMC.
Error Message Descripon Possible Soluons
Refrig Sensor # Open A temperature sensor or harness is considered to have an
open electrical connecon. Where # is the sensor number.
Check sensor and sensor harness for open
connecons. Check for sensor readings. Replace
sensor if necessary.
Refrig Sensor # Short A temperature sensor or harness is considered to have an
electrical short. Where # is the sensor number.
Check sensor and sensor harness for shorted
connecons. Replace if necessary.
Refrig Health Safety The cabinet temperature and me limit sengs have been
exceeded.
Check sensor readings and sensor harness for
shorted connecons. Check for sensor readings.
Replace sensor if necessary.
Error Message Descripon Possible Soluons
Opcal Sensor Error The vend sensor is blocked, out of alignment
or not detected.
Check sensor and sensor harness for open connecons. Check for
sensor readings. Replace sensor if necessary.
Coin Mech Comm VMC does not have communicaon with the coin changer. Check MDB Harness to changer. Check for power
on changer. See changer service manual.
Coin Mech Tube Sns The coin changer has reported a tube sensor error. See changer service manual.
Coin Mech Inlet The coin changer has reported an acceptor blockage. Check changer tubes. See changer service manual.
Coin Mech Tube Jam The coin changer has reported a tube payout error. Check changer tubes. See changer service manual.
Coin Mech ROM The coin changer has reported a program memory error. See changer service manual.
Coin Mech Excess Esc The coin changer has reported that a large number of coin
escrow requests have occurred.
Check changer escrow lever posion.
Coin Mech Coin Jam The coin changer has reported that a coin is jammed in the
coin path.
Check changer coin path. See changer service
manual.
Coin Mech Low Accept The VMC has seen a low acceptance rate on coins. Review inserted coins. See changer service manual.
Coin Mech Accpt Disc The coin changer has reported that the coin validaon
acceptor is disconnected.
Re-connect the coin changer’s acceptor. See
changer service manual.
Coin Mech Route Err The coin changer reported that a coin did not follow the
correct path.
Check changer coin path. See changer service
manual.