44Revision 2.EL950 1.3.1074C 18.6
ENERGY SAVINGS
Use this menu to set a non-health safety machine to run at a higher than normal temperature during set
mes. This will save energy during o peak hours of sales. Two intervals are available.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 6 for Password (Advanced Features) Menu Password
3. Enter Password (default 2314) Advanced Features
4. Press 6 for Energy Savings Energy Savings
5. Press 1 for Interval1 (2 for Interval2, and so on) Interval1
6. Press 4 for Day menu Day
7. Press 1 for All Days All Days (Current Seng *-Exit 1-Edit
8. Press 1 to toggle All Days ON/OFF All Days (New Seng) *-Exit #-Save
9. Press # to save the seng All Days (New Seng) *-Exit 1-Edit
10. Press 2 to toggle Monday ON/OFF Mon (Choice Flashing) *-Exit 2-Edit
11. Press # to save the seng Mon (New Seng) *-Exit 2-Edit
12. Press * two mes to return to Interval1 menu Interval1
13. Press 5 two mes for Start Time menu (Current Time) *-Exit 5-Edit
14. Press 5, then enter Start Time in 24-hr me (HH:MM) New Time *-Exit #-Save
15. Press # to save the me New Time *-Exit 5 -Edit
16. Press * two mes to return to Energy Savings menu Energy Savings
17. Press 6 two mes for Stop Time menu Stop Time
18. Press 6, then enter Stop Time in 24-hr me (HH:MM) New Time *-Exit #-Save
19. Press # to save the me New Time *-Exit 6 -Edit
20. Press * to return to Interval1 menu Interval1
21. Press 7 to enter Storage Temp (default is 62° F) Storage (Current Temp) F *-Exit 7-Edit
22. Press 7 to set Storage Temp (36° F to 62° F) Storage (Choice Flashing) F *-Exit #-Save
23. Press # to save the seng Storage (New Temp) F *-Exit 7-Edit
24. Press * once to return to Interval1 Menu Interval1
25. Press 8 for Lighng menu Lighng (Current Seng) *-Exit 8-Edit
26. Press 8 to toggle Lighng ON/OFF Lighng ON turns o lights during Energy
Saving interval Lighng OFF leaves lights on during Energy Saving interval
Lighng (Choice Flashing) *-Exit 8-Edit
27. Press # to save the seng Lighng (New Seng *-Exit 8-Edit
28. Press * ve mes to exit to Sales Mode 0.00