55QB218 6.1.2019 vers 1.0
5. Press 1 for current Max Change seng
Max Change (Current Seng)
*-Exit 1-Edit
6. Press 1 to toggle ON/OFF
Max Change (Choice Flashing)
*-Exit #-Save
7. Press # to save the seng
Max Change (New Seng)
*-Exit 1-Edit
8. Press 2 and enter dollar amount
Max Change: $--.—
*-Exit #-Save
9. Press # to save the seng
Max Change (New Seng)
*-Exit 2-Edit
7. Press * three mes to exit 0.00
SHUTDOWN
This menu sets the VMC to shut down All Items, by Row or by Selecon, based on four (4) me of day
intervals. If the me falls within one of these intervals and the enre machine has been selected
for shutdown, then the message, “Vending Operaon to Resume at hh.mm,” will be displayed.
If a row or individual selecon has been set for Shutdown, the same message displays once every me
the customer makes that selecon or selecons (row).
NOTE: the correct me and date must be set so that the shutdown intervals work correctly. See Time
and Date secon of this manual. Also, for any given day these four me intervals may overlap
each other. For each interval, the VMC can be programmed from no days up to every day
of the week on which the specied shutdown me intervals are acve.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2.
Press 6 for Password (Advanced Features)
Menu
Password
3. Enter Password (default 2314) Advanced Features
4. Press 5 for Shutdown Shutdown
5.
Press 1 for Interval1 (2 for Interval2, and so
on)
Interval1
6. Press 1 to for All Items
All Items (Current Seng)
*-Exit 1-Edit
7. Press 1 to toggle ON/OFF
All Items (Choice Flashing)
*-Exit #-Save
8. Press # to save the seng
All Items (New Seng)
*-Exit 1-Edit
9. Press * to return to Interval1 Interval1
10. Press 4 for Day menu Day
11. Press 1 for All Days
All Days (Current Seng
*-Exit 1-Edit
12. Press 1 to toggle All Days ON/OFF
All Days (New Seng)
*-Exit #-Save