EasyManua.ls Logo

Seagate Exos 7E10 - LBA Mode; Recording and Interface Technology; Start;Stop Times

Seagate Exos 7E10
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Seagate Exos 7E10 Serial ATA Product Manual, Rev. B 11
2.2.2 LBA mode
When addressing these drives in LBA mode, all blocks (sectors) are consecutively numbered from 0 to n–1, where n is the number of
guaranteed sectors as defined above.
See Section 6.3.1, "Identify Device command" (words 60-61 and 100-103) for additional information about 48-bit addressing
support of drives with capacities over 137GB.
2.3 Recording and interface technology
2.4 Start/stop times
Power-on to ready time is based on typical operating conditions, default full current spin-up profile, and clean shutdown prior to
measurement. To ensure a clean shutdown a Flush Cache, Standby, or Standby Immediate command must be completed before
removal of interface power.
An unexpected power loss event, spin up at cold or hot temperature extremes may cause the drive to exceed the typical and max
time to ready by 5 to 20 seconds. Extended time to ready is dependent on cache state and environmental conditions prior to the
unexpected power loss and during the subsequent power on.
Interface Serial ATA (SATA)
Recording method Perpendicular
Recording density, KBPI (Kb/in max) 2499
Track density, KTPI (ktracks/in, 0 Skew) 487
Areal density (Gb/in
2
, @ 0 skew mid-disk) 1215
Spindle speed (RPM) (± 0.2%) 7200
Internal data transfer rate (Mb/s max) 2169
Sustained data transfer rate (MiB/s max) (10TB models) 251 (263 MB/s max)
Sustained data transfer rate (MiB/s max) (8TB models) 243 (255 MB/s max)
Sustained data transfer rate (MiB/s max) (6TB & 4TB models) 229 (250 MB/s max)
Sustained data transfer rate (MiB/s max) (2TB models) 216 (226 MB/s max)
I/O data-transfer rate (MB/s max) 600 (Ultra DMA mode 5)
Power-on to Ready (sec) (typ/max) 23/30
Standby to Ready (sec) (typ/max) 23/30
Ready to spindle stop (sec) (max) 20

Table of Contents

Related product manuals