Left-Hand Unit (GT024-72H*L) Instructions:
1. Remove and retain end and side panels. See Fig. 6.
2. Disconnect blower motor wiring and ground wire fastened
to blower housing. See Fig. 7.
3. Remove and retain bracket by removing (3) screws. See
Fig. 8.
4. Loosen blower assembly by removing (4) screws. See Fig.
9.
5. Remove and retain bracket by removing (2) screws. See
Fig. 10.
6. Rotate the blower into its new position. See Fig. 11.
Fig. 6 - Side Panel Removal
A14036
A14037
Fig. 7 - Blower Motor Wring & Ground Wire Location
Fig. 9 - Screws Holding Blower Assembly
Fig. 10 - Screws Holding Blower Bracket
A14039
A14040
_)))))))i
Fig. 11 - Rotate Blower Into New Position
A14041
Fig. 8 - Screws Holding Bracket
A14038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sears GT Series and is the answer not in the manual?

Sears GT Series Specifications

General IconGeneral
Heating CapacityVaries by model, typically between 18, 000 BTU/h and 60, 000 BTU/h
Cooling CapacityVaries by model, typically between 18, 000 BTU/h and 60, 000 BTU/h
SEER RatingVaries by model, typically between 13 and 16
HSPF RatingVaries by model, typically between 7.0 and 8.5
StagesSingle-stage or Two-stage (depending on the specific model)
RefrigerantR-22 or R-410A (depending on the specific model and year of manufacture)
WarrantyVaries, typically 1-year parts and labor, 5-year compressor (check specific model details)