1. Introduction to DSO203 Oscilloscope
DS203 is a pocket size 4-channel digital storage oscilloscope for common electronic engineering
tasks. Its CPU is an ARM Cortex M3, STM32VCT6, with an AD9288-40 dual A/D converter
sampling at 72 MHz, and a customer FPGA to manage the ADC and data buffering. A built-in 2MB
USB disk enables you to store waveforms and to upgrade firmware. It also provides 4 application
areas, convenient for users to load and upgrade at most 4 different application firmware. Schematics
and source files are open-sourced to encourage improvements and innovations.
Major Features
This pocket-size oscilloscope DSO203 helps you test electronic devices, and measure relevant
electronic signal. Its features include:
Full color 3” TFT LCD display, 400x240 pixels.
8 MHz ADC bandwidth8-bit precision.
2 analog channels: (CH_A, CH_B) and 2 digital channels (CH_C, CH_D).
Integrated Square/Sine/Triangle/Sawtooth signal generator.
Calculation channels: [CH_A]+[CH_B], [CH_A]-[CH_B], Logic OR [CH_C]|[CH_D], Logic
AND [CH_C]&[CH_D], REC_A, REC_B, REC_C, REC_D.
Maximum sampling rate of a single analog channel, 72 MS/s.
Maximum record length of any channel, 4096 points.
Waveforms and upgrade firmware can be stored in built-in 2M USB disk.
Rechargeable battery powered by USB connection.
Comprehensive user interface through 6 buttons/switches and colored menu control system.
2 mcx 1X/10X oscilloscope probes.
Safety
To ensure your safety & avoid any damage to the device/connected products, please read the
following precautions carefully. To avoid any possible dangers, please use this product according to
the following rules.
Avoid fire and physical injury.
Use supplied USB cord for power.
Connect and disconnect properly. Do not plug/unplug when the probe(s)/test lead(s) is
connected to the voltage sources. Before you plug/unplug current probes, disconnect power to the
circuit-under-test.
Observe all terminal ratings. To avoid fire/electric shock, please observe ratings & symbols on
the product. Please read the user’s manual carefully to determine the ratings before connecting
the device.
Do not operate in humid environment.
Do not operate in inflammable/explosive environment.
Keep the surface of the product clean and dry.
Operation Conditions
TemperatureOperating Condition0 to +50°C; Non-operating Condition-20 to +60 °C.
HumidityOperating Conditionhigh temperature40 to 50 °C0 to 60% RH; Operating
Conditionlow temperature0 to 40 °C10 to 90%RH; Non-operating Conditionhigh
temperature40 to 60 °C5 to 60% RH; Non-operating Conditionlow temperature0 to 40
° C 5 to 90% RH
Electrical Ratings: Max transient voltage, ± 400 V peak; Measure voltage range, ±15 V peak;