www.seuservice.com
31
INPUT TEST
HANDLE BAR 0H
ROLL 0H
THROTTLE LEVER FFH
PITCH 0H
START OFF
VIEW OFF
SAFETY SENSOR OFF
SERVICE OFF
TEST OFF
PRESS TEST AND SERVICE BUTTON TO EXIT
INPUT TEST
When INPUT TEST is selected, the following screen appears on the monitor. The screen allows the
status of each SW and the value of each V.R. of the cabinet to be viewed.
On this screen, periodically check the status of each switch & V.R.
• By pressing each switch, if the display on the
right-hand side of the name of each switch
changes to ON from OFF, the SW and the wiring
connections are satisfactory.
• Simultaneously pressing the Service button and
the Test button returns the Game Test Menu
screen.
The standard values for adjusting each V. R. are as follows:
In this product, the item of VOLUME SETTING allows V. R. values except for PITCH to be set.
THROTTLE LEVER:e 0 H + 9 (lever released)
Without a moving base you will not be able to do ROLL, PITCH, or SAFETY SENSOR.