151
MAINTENANCE,STORAGE AND TRANSPORTATION
1. Remove the 2 battery pull straps
2. Turn up the Protective rubber sleeve
.
3. Remove the battery negative pole screw and disconnect the
black (negative) battery cable.
4. Remove the battery positive pole screw and disconnect the
red (positive) battery cable.
5. Remove the battery.
Battery Charging
NOTICE
When charging, the hydrogen produced by the 12V battery is
combustible explosive gas. Please follow the following precautions
before charging:
If charging the 12V battery is still installed in the vehicle, be sure to
disconnect the ground cable.
Make sure the power switch on the charger is off when connecting and
disconnecting the charger cable to the 12V battery.
Only charge slowly (5A or less), if not the 12V battery may explode.
Measures to be taken in an emergency
1. Connect the clamp of the positive jumper cable to the special
jumper starting terminal of the vehicle.
2. Connect the clamp on the other end of the positive cable to
the positive (+) terminal of another vehicle.
3. Connect the negative cable clamp to the negative battery
terminal of another vehicle.
4. As shown, connect the clamp on the other end of the negative

Table of Contents