11
508.366.1488 | www.semshred.com
RESET pushbutton and the STOP pushbutton.
4.) To restart the unit, press the RESET pushbutton. When the unit is ready to run, the RESET button will
extinguish.
5.) Next, press the START pushbutton to restart the unit. If the unit is still jammed, the media may have to
be removed manually.
6.) To release the jam, de-energize the unit (recommended that each site has a LOTO program in place),
then unbolt and remove the top cover to gain access to the STAGE 1 chamber. SEM recommends using
long pliers.
7.) Remove the solid state drive and/or remaining particles. Bolt the top cover back into place.
8.) Follow the startup procedures to restart the unit.