2. After installation, configure the thermostat to the
appropriate system type. Press “Menu” on the thermostat
and refer to these menu options as needed:
CONFIGURATION MENU ITEMS REFERENCE
Display
Code
Menu item Default Options
Wireless Setup
Connects Thermostat
to Wi-Fi network
Connect
Fahrenheit or Celsius F F
C
Outdoor Equipment
Configuration
Cooling or heat pumps
AC2 AC1 – Conventional Cooling 1
(Single Stage)
AC2 Conventional Cooling 2
(Two-Stage)
HP1 – Heat Pump 1 (Single Stage)
HP2– Heat Pump 2 (Two-Stage)
AC0 No Cooling
Indoor Equipment
Configuration
For Gas or Electric Heat
EL2 EL1– Electric 1 (Single Stage)
EL2– Electric 2 (Two-Stage)
FAn
GA1 Gas 1 (Single Stage)
GA2 Gas 2 (Two-Stage)
Reversing Valve Position
Selects “O” or “B” Setting
For Heat Pumps Only
O O
B
2
Fn Circulating Fan OFF Off/10% – 100% (5% increments)
H AA Humidification
Add Accessory
OFF Off/On
H SP Humidification
Set Point
OFF Off/5% – 50% (5% increments)
dH AA Dehumidification
Add Accessory
Od Od/Oc
Od – Optimal dehumidification
(Overcool to dehumidify)
Oc – Optimal comfort
(Wired dehumidification)
dH SP Dehumidification
Set Point
OFF Off/40% – 95% (5% increments)
Wireless Radio
Turns Wi-Fi Radio On/Off
ON Off/On