27
6. Route the cables neatly in the channels on the rear of the DIN
adapter. Fit the bungs provided into any unused channels.
7. Fit the cable access cover over the cables and any bungs, using the
screws provided.
PZ-2
Din Mount Kit and IP55 Sealing
If required for the installation, the SCC3 can be further protected so that
it is sealed against front water ingress to IP55 standards when mounted
using the DIN mount kit.
8. Push the assembly fully into the DIN cage.
To remove, use the DIN
release tools (provided)
CAUTION! Ensure all bungs have been tted into
unused channels on the SCC3 and mount kit, and that
the appropriate sizes have been used. Bungs have
a raised prole on their upper surface. When tting,
ensure that the position of its raised prole matches
that of the moulded prole on either side of the
channel being blocked.