safety precauons and usage statements
IN-HOME USE AND HOSPITAL STANDARDS
Ergomoon adjustable bed bases are designed solely for in-home use. This base was not
designed as a hospital bed and is not designed to meet hospital standards. Do not use
this base with TENT TYPE oxygen therapy equipment or near explosive gases.
ADDITIONAL SAFETY FEATURES
Casters (oponal leg accessory) are equipped with locking wheels to prevent
unwanted movement. Even when locked and unable to roll, it is possible for the
casters to slide. Free release head and foot motors are designed to lower the maress
by retracng only with gravity, never pulling downwards, which minimizes pinch
points.
ACOUSTICS
LIFTING/LOWERING MECHANISMS
The li/lower feature will emit a minimal humming sound during operaon. This is
normal. During operaon, the li arm wheels make contact with the plaorm support
of the base. This contact may result in metal on metal or metal on plasc contact.
This applies slight tension on the moving components and resonance is reduced to a
minimum level. If excessive noise or vibraon is experienced, reverse the movement
acon (up or down) of the base with the remote control. This should realign the
base’s acvang mechanisms to the proper operaonal posion. In normal base
operaon, the wheels, which allow the bed to maintain its distance from the wall, will
make contact with the steel plaorm supports of the base creang a contact noise.
When entering, exing or shiing weight on the base, this contact noise may be
audible as the wheels make contact. This is normal.
MATERIALS
Ergomoon adjustable bases are constructed from various materials including woods,
metals, plascs and fabrics. Tension, pressure or movement applied to the frame,
plaorm or shroud through general use may create an audible sound.
TOLERANCE
All Ergomoon adjustable foundaons, depending on make and model, are designed
and manufactured to perform and funcon within designated quality control
parameters. Bases are subject to meculous and rigorous inspecons during the
quality control process to ensure bases will operate within these standards during
normal operang use. Normal operang use is dened as the following: Adjustable
foundaon is to be operated with a maress and load. Tesng procedures require
lifeme cycle tests with up to 120 kg distributed load. The angle (designated “a” in
gure 1) between the back secon and the at secon for various conguraons of
the maress support plaorm shall be ± 3°, which translates to a tolerance of up to 1
½”.
The angle (designated “b” in gure 1) between the at secon and foot secon for
various conguraons of the maress support plaorm shall be ± 3°, which translates
to a tolerance of up to ¾”.
WARNING
For optimal safety and operation, plug bed base into a surge protector (not included).
The bed base should only be plugged directly into a grounded wall outlet or surge
protector (strongly recommended). Improper connection of the equipment can result in
the risk of electrical shock, electrical file or faulty operation of this bed base. If the plug
does not fit your outlet, contact a qualified Electrician to install a suitable outlet.
Adjustable
Bed Tolerance
Ergomotion Inc. | ph 1-888-550-3746 | fx 805-979-9399 | www.ergomotion.com
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these standards during normal operating use.
Normal operating use is defined as the following:
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
tests with up to 120kg distributed load.
The angle (designated αin figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½”.
The angle (designated βin figure 1) between the flat section and foot section for various configurations of the mattress
support platform shall be ± 3°, which translates to a tolerance of up to ¾”.
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturers
quality control standards.
(α°)
(β°)
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
Blake Pettit
Quality Assurance Manager